Use of inverter drive for rotating machines speed control leads to the application of new stress on stator insulation materials. The integrity of these materials under such stresses has therefore to be studied. Thanks to specially equipped motor, the different voltage shapes have been identified. Very short rise time fronts, large overvoltages and high oscillation frequencies are obtained. These voltages are then reproduced on laboratory samples (Polyethylene Terephtalate). The main result is the existence of trapped surface charges related both to the rise front value and to the existence of polar mechanisms in the material bulk. The consequences of this surface charge existence on the reliability of a real system are then discussed.