Single-Lung Transplant Results in Position Dependent Changes in Regional Ventilation: An Observational Case Series Using Electrical Impedance Tomography
Open Access
- 30 June 2016
- journal article
- research article
- Published by Hindawi Limited in Canadian Respiratory Journal
- Vol. 2016, 1-6
Abstract
Background. Lung transplantation is the optimal treatment for end stage lung disease. Donor shortage necessitates single-lung transplants (SLT), yet minimal data exists regarding regional ventilation in diseased versus transplanted lung measured by Electrical Impedance Tomography (EIT).Method. We aimed to determine regional ventilation in six SLT outpatients using EIT. We assessed end expiratory volume and tidal volumes. End expiratory lung impedance (EELI) and Global Tidal Variation of Impedance were assessed in supine, right lateral, left lateral, sitting, and standing positions in transplanted and diseased lungs. A mixed model with random intercept per subject was used for statistical analysis.Results. EELI was significantly altered between diseased and transplanted lungs whilst lying on right and left side. One patient demonstrated pendelluft between lungs and was therefore excluded for further comparison of tidal variation. Tidal variation was significantly higher in the transplanted lung for the remaining five patients in all positions, except when lying on the right side.Conclusion. Ventilation to transplanted lung is better than diseased lung, especially in lateral positions. Positioning in patients with active unilateral lung pathologies will be implicated. This is the first study demonstrating changes in regional ventilation, associated with changes of position between transplanted and diseased lung.Keywords
This publication has 9 references indexed in Scilit:
- The value of electrical impedance tomography in assessing the effect of body position and positive airway pressures on regional lung ventilation in spontaneously breathing subjectsIntensive Care Medicine, 2005
- Functional Analysis in Single-Lung Transplant RecipientsChest, 2004
- End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume changeIntensive Care Medicine, 2003
- Detection of local lung air content by electrical impedance tomography compared with electron beam CTJournal of Applied Physiology, 2002
- Angiotensin II formation and endothelin clearance in ARDS patients in supine and prone positionsIntensive Care Medicine, 2000
- Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomographyActa Anaesthesiologica Scandinavica, 1998
- Ventilation distribution during histamine provocationJournal of Applied Physiology, 1997
- Monitoring changes in lung air and liquid volumes with electrical impedance tomographyJournal of Applied Physiology, 1997
- Regional intrapulmonary gas distribution in awake and anesthetized-paralyzed manJournal of Applied Physiology, 1977