Adaptive template matching of photoplethysmogram pulses to detect motion artefact
- 1 October 2018
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 39 (10) , 105005
Abstract
Objective : The photoplethysmography (PPG) signal, commonly used in the healthcare settings, is easily affected by movement artefact leading to errors in the extracted heart rate and SpO 2 estimates. This study aims to develop an online artefact detection system based on adaptive (dynamic) template matching, suitable for continuous PPG monitoring during daily living activities or in the intensive care units (ICUs). Approach : Several master templates are initially generated by applying principal component analysis to data obtained from the PhysioNet MIMIC II database. The master template is then updated with each incoming clean PPG pulse. The correlation coefficient is used to classify the PPG pulse into either good or bad quality categories. The performance of our algorithm was evaluated using data obtained from two different sources: (i) our own data collected from 19 healthy subjects using the wearable Sotera Visi Mobile system (Sotera Wireless Inc.) as they performed various movement types; and (ii) ICU data provided by the PhysioNet MIMIC II database. The developed algorithm was evaluated against a manually annotated ‘gold standard’ (GS). Main results : Our algorithm achieved an overall accuracy of 91.5% ± 2.9%, with a sensitivity of 94.1% ± 2.7% and a specificity of 89.7% ± 5.1%, when tested on our own data. When applying the algorithm to data from the PhysioNet MIMIC II database, it achieved an accuracy of 98.0%, with a sensitivity and specificity of 99.0% and 96.1%, respectively. Significance : The proposed method is simple and robust against individual variations in the PPG characteristics, thus making it suitable for a diverse range of datasets. Integration of the proposed artefact detection technique into remote monitoring devices could enhance reliability of the PPG-derived physiological parameters.Keywords
Funding Information
- The Ministry of Education, Fundamental Research Grant Scheme (FP008-2016)
This publication has 19 references indexed in Scilit:
- Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlationPhysiological Measurement, 2012
- Dynamic time warping and machine learning for signal quality assessment of pulsatile signalsPhysiological Measurement, 2012
- Signal quality measures for pulse oximetry through waveform morphology analysisPhysiological Measurement, 2011
- Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometryPhysiological Measurement, 2010
- Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiographyJournal of Medical Engineering & Technology, 2008
- A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion statesMedical & Biological Engineering & Computing, 2006
- A new method for pulse oximetry possessing inherent insensitivity to artifactIEEE Transactions on Biomedical Engineering, 2001
- Accuracy of pulse oximetry during intense exercise under severe hypoxic conditionsEuropean Journal of Applied Physiology, 1997
- Biochemical assessment of sympathetic activity and prejunctional modulation of noradrenaline release in humansJournal Of Hypertension, 1996
- Falsely Normal Saturation Reading with the Pulse OximeterAnesthesiology, 1987