Comparison between 50 Hz AC and DC vacuum breakdown
Author:
- 11 March 1975
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 8 (4) , L53-L55
Abstract
The DC breakdown voltage of an ultrahigh vacuum gap is measured using a silver alloy and found to increase to the level of the peak AC (50 Hz) voltage after 'conditioning' by repeated sparkings of both electrodes. The conditioning of the electrodes in high vacuum is done in two separate experiments with AC sparkings and using both polarities of the DC applied voltage. The equality of the DC and AC dielectric strength of the vacuum gap is confirmed over a wide range of gap distances.Keywords
This publication has 3 references indexed in Scilit:
- Polarity Effect in Vacuum Breakdown Electrode ConditioningJournal of Applied Physics, 1965
- The electrical breakdown in vacuumApplied Scientific Research, Section B, 1961
- THE ELECTRICAL BREAKDOWN OF SMALL GAPS IN VACUUMCanadian Journal of Physics, 1958