An improved control strategy based on multiplier for CRM flyback PFC to reduce line current peak distortion
Authors:
- 1 September 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 901-905
Abstract
With high input voltage or light load, the peak of AC line current for critical conduction mode (CRM) flyback power factor Correctors (PFCs) appears notably distorted. In this paper, the reasons of line current distortion are investigated. Moreover, the relationship between line current peak distortion and high input voltage or light load is presented. Based on theoretical analysis, a simple improved control strategy is proposed. Finally, an experiment is carried out and the results convincingly demonstrate the effectiveness of the proposed method for reducing line current peak distortion.Keywords
This publication has 5 references indexed in Scilit:
- Powering LED Using High-Efficiency SR Flyback Converter2009
- A novel control method for interleaved transition mode PFC2008
- Line current distortions of DCM/CCM boundary boost PFC converter2008
- A very simple control strategy for power factor correctors driving high-brightness light-emitting diodesAPEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and Exposition, 2008
- Variable On-time Control of the Critical Conduction Mode Boost Power Factor Correction Converter to Improve Zero-crossing Distortion2006