Test-Retest and Inter-Rater Reliability of a Rotary Axis Encoder-Flywheel System for the Assessment of Hip Rotation Exercises
Authors:
- Silvia Lahuerta-MartínSLSilvia Lahuerta-Martín
- Elena Esteban-LozanoEEElena Esteban-Lozano
- Sandra Jiménez-Del-BarrioSJSandra Jiménez-Del-Barrio
- Román Robles-PérezRRRomán Robles-Pérez
- María Teresa Mingo-GómezMMMaría Teresa Mingo-Gómez
- Luis Ceballos-LaitaLCLuis Ceballos-Laita
- Ignacio Hernando-GarijoIHIgnacio Hernando-Garijo
Open Access
- 30 December 2023
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 14 (1) , 372
Abstract
Background: Flywheel devices have found extensive use as a resistance training method. Performance monitoring during functional exercises can be achieved through a coupled rotary axis encoder. However, the reliability of a rotary axis encoder-flywheel system remains underexplored for isolated movements. This study aims to assess test-retest and inter-rater reliability of a rotary axis encoder-flywheel system for assessing hip rotation movements. Methods: Twenty-nine physically active participants were included. The Conic Power Move® flywheel was used to perform hip internal and external rotation exercises. Mean and peak values for velocity, force, and power were collected using a Chronojump rotary axis encoder and the Chronojump software v.2.2.1. The intraclass correlation coefficient (ICC) and the coefficient of variation (CV) were calculated to assess relative and absolute reliability, respectively. Standard error of measurement and minimum detectable changes were also calculated. Results: Good to excellent ICCs (0.85–0.98) were achieved for test-retest and inter-rater reliability in all outcomes for both hip internal and external rotation exercises. There was acceptable test-retest absolute reliability (CV < 10%) for mean and peak velocity, and mean force of hip internal and external rotation (CV = 4.7–7%). Inter-rater absolute reliability was acceptable for mean and peak velocity, mean power, and mean force (CV = 4.7–9.8%). Conclusion: The rotational encoder-flywheel system demonstrated good to excellent relative reliability for assessing hip rotation exercises. Peak force and power values exhibit absolute reliability >10%, so the use of mean and peak velocity, mean force, and mean power seems more adequate for measurements with the rotary axis encoder-flywheel system.Keywords
This publication has 36 references indexed in Scilit:
- Quantification of the forearm muscles mechanical properties using Myotonometer: Intra- and Inter-Examiner reliability and its relation with hand grip strengthJournal of Electromyography and Kinesiology, 2022
- Validity and reliability of a flywheel squat test in sportJournal of Sports Sciences, 2020
- Post‐activation potentiation (PAP) in endurance sports: A reviewEuropean Journal of Sport Science, 2018
- Characterising overload in inertial flywheel devices for use in exercise trainingSports Biomechanics, 2018
- Effects of adding a weekly eccentric‐overload training session on strength and athletic performance in team‐handball playersEuropean Journal of Sport Science, 2017
- Intrarater reliability of hand held dynamometry in measuring lower extremity isometric strength using a portable stabilization deviceMusculoskeletal Science and Practice, 2017
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- What is the Best Method for Assessing Lower Limb Force-Velocity Relationship?International Journal of Sports Medicine, 2014
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedJournal of Clinical Epidemiology, 2011
- Test–retest reliability of cardinal plane isokinetic hip torque and EMGJournal of Electromyography and Kinesiology, 2009