Review of the current status of radiation protection in diagnostic radiology in Africa
- 12 June 2017
- journal article
- review article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 4 (3) , 031202
Abstract
The aim of this paper is to review the available published studies from African countries on patient doses and medical radiation protection and identify strengths, weaknesses, and challenges. Papers on radiation doses to patients published until 2016 pertaining to studies in African countries were reviewed. Radiography, interventional radiology, computed tomography (CT), and mammography modalities were covered. In radiography, the entrance surface air kerma values were below the established diagnostic reference levels (DRLs) provided by the International Atomic Energy Agency, European Commission, and National Council on Radiation Protection and Measurements. Patient and staff doses in interventional procedures were not on the higher side when compared with other published reports from developed countries. The dose length product values in CT in many situations were higher than established DRLs. In mammography, the variations of clinical image quality and dose to standard breast between African countries and other countries were insignificant. In conclusion, like in any continent, not all countries in Africa are active, but some have produced good results. The potential for optimization of radiation protection using simple and inexpensive techniques has been demonstrated. The lack of medical physicists is one of the important challenges.Keywords
This publication has 30 references indexed in Scilit:
- International Atomic Energy Agency study with referring physicians on patient radiation exposure and its tracking: a prospective survey using a web-based questionnaireBMJ Open, 2012
- Patient doses in interventional cardiology procedures in SudanRadiation Protection Dosimetry, 2012
- IAEA Survey of Pediatric CT Practice in 40 Countries in Asia, Europe, Latin America, and Africa: Part 1, Frequency and AppropriatenessAmerican Journal of Roentgenology, 2012
- International action plan on the radiation protection of patientsRadiation Protection Dosimetry, 2011
- Impact of the International Atomic Energy Agency (IAEA) actions on radiation protection of patients in many countriesRadiation Protection Dosimetry, 2011
- Trends in Coronary Revascularization in the United States From 2001 to 2009Circulation: Cardiovascular Quality and Outcomes, 2011
- Radiological Protection in Fluoroscopically Guided Procedures Performed Outside the Imaging DepartmentAnnals of the ICRP, 2010
- Paediatric CT examinations in 19 developing countries: frequency and radiation doseRadiation Protection Dosimetry, 2010
- Patient doses in CT Examinations in 18 countries: initial results from international atomic energy agency projectsRadiation Protection Dosimetry, 2009
- Radiation Exposure to Patients During Interventional Procedures in 20 Countries: Initial IAEA Project ResultsAmerican Journal of Roentgenology, 2009