Optimized protocol of a frequency domain fluorescence lifetime imaging microscope for FRET measurements
- 15 December 2008
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 72 (5) , 371-379
Abstract
Frequency‐domain fluorescence lifetime imaging microscopy (FLIM) has become a commonly used technique to measure lifetimes in biological systems. However, lifetime measurements are strongly dependent on numerous experimental parameters. Here, we describe a complete calibration and characterization of a FLIM system and suggest parameter optimization for minimizing measurement errors during acquisition. We used standard fluorescent molecules and reference biological samples, exhibiting both single and multiple lifetime components, to calibrate and evaluate our frequency domain FLIM system. We identify several sources of lifetime precision degradation that may occur in FLIM measurements. Following a rigorous calibration of the system and a careful optimization of the acquisition parameters, we demonstrate fluorescence lifetime measurements accuracy and reliability. In addition, we show its potential on living cells by visualizing FRET in CHO cells. The proposed calibration and optimization protocol is suitable for the measurement of multiple lifetime components sample and is applicable to any frequency domain FLIM system. Using this method on our FLIM microscope enabled us to obtain the best fluorescence lifetime precision accessible with such a system. Microsc. Res. Tech., 2009.Keywords
This publication has 27 references indexed in Scilit:
- Calibration of a wide‐field frequency‐domain fluorescence lifetime microscopy system using light emitting diodes as light sourcesJournal of Microscopy, 2006
- Setup and characterization of a multiphoton FLIM instrument for protein–protein interaction measurements in living cellsCytometry Part A, 2006
- Multi‐dimensional time‐correlated single photon counting (TCSPC) fluorescence lifetime imaging microscopy (FLIM) to detect FRET in cellsJournal of Microscopy, 2004
- Low‐cost, frequency‐domain, fluorescence lifetime confocal microscopyJournal of Microscopy, 2004
- Fluorescence lifetime imaging by time‐correlated single‐photon countingMicroscopy Research and Technique, 2003
- Fluorescence lifetime imaging for the two-photon microscope: time-domain and frequency-domain methodsJournal of Biomedical Optics, 2003
- Fluorescence lifetime imaging: multi-point calibration, minimum resolvable differences, and artifact suppressionCytometry, 2001
- Principles of Fluorescence Spectroscopy1999
- Fluorescence lifetime imaging microscopy (FLIM): Spatial resolution of microstructures on the nanosecond time scaleBiophysical Chemistry, 1993
- Fluorescence lifetime imaging using a confocal laser scanning microscopeScanning, 1992