3D MDEFT imaging of the human brain at 4.7 T with reduced sensitivity to radiofrequency inhomogeneity
Open Access
- 19 May 2005
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (6) , 1452-1458
Abstract
A modification to the 3D modified driven equilibrium Fourier transform (MDEFT) imaging technique is proposed that reduces its sensitivity to RF inhomogeneity. This is especially important at high field strengths where RF focusing effects exacerbate B1 inhomogeneity, causing significant signal nonuniformity in the images. The adiabatic inversion pulse used during the preparation period of the MDEFT sequence is replaced by a hard (nonadiabatic) pulse with a nominal flip angle of 130°. The spatial inhomogeneity of the hard pulse preparation compensates for the inhomogeneity of the excitation pulses. Uniform signal intensity is obtained for a wide range of B1 amplitudes and the high CNR characteristic of MDEFT is retained. The new approach was validated by numerical simulations and successfully applied to human brain imaging at 4.7 T, resulting in high‐quality T1‐weighted images of the whole human brain at high field strength with uniform signal intensity and contrast, despite the presence of significant RF inhomogeneity. Magn Reson Med 53:1452–1458, 2005.Keywords
This publication has 18 references indexed in Scilit:
- High‐resolution fast spin echo imaging of the human brain at 4.7 T: Implementation and sequence characteristicsMagnetic Resonance in Medicine, 2004
- Ultrahigh field magnetic resonance imaging and spectroscopyMagnetic Resonance Imaging, 2003
- High field human imagingJournal of Magnetic Resonance Imaging, 2003
- High resolution MRI of the brain at 4.7 Tesla using fast spin echo imagingBritish Journal of Radiology, 2003
- 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head imagesMagnetic Resonance in Medicine, 2001
- Sensitivity and Power Deposition in a High-Field Imaging ExperimentJournal of Magnetic Resonance Imaging, 2000
- Functional mapping in the human brain using high magnetic fieldsPhilosophical Transactions of the Royal Society B: Biological Sciences, 1999
- MR relaxation times in human brain: measurement at 4 T.Radiology, 1996
- High contrast and fast three‐dimensional magnetic resonance imaging at high fieldsMagnetic Resonance in Medicine, 1995
- The field dependence of NMR imaging. I. Laboratory assessment of signal‐to‐noise ratio and power depositionMagnetic Resonance in Medicine, 1986