Effects of perfluorochemical evaporative properties on oxygenation during partial liquid ventilation
- 1 December 2006
- journal article
- research article
- Published by Wiley in Pediatrics International
- Vol. 48 (6) , 608-615
Abstract
The physical-chemical properties of perfluorochemical (PFC) liquids have been shown to influence physiological and cellular responses during partial liquid ventilation (PLV). The aim of this study is to compare the relationship between patho-physiological endpoints and the physical properties of three PFC liquids used in treating acute lung injury. A total of 18 juvenile rabbits were randomized into conventional mechanical ventilation or PLV groups after lung saline lavages. Three PFC liquids, including Flutec perfluoro-1,3,5-trimethylcyclohexane (PP4; vapor pressure, 28.8 mmHg at 37 degrees C), Perfluorodecalin (PFD; vapor pressure, 13.6 mmHg at 37 degrees C), and Perflubron (PFB; vapor pressure, 10.4 mmHg at 37 degrees C) were used for PLV with no replacement for 4 h. A thermal detector was used to measure PFC loss rate. Physiological measurements and evaporative loss rate of PFC were done every 30 min, and lung histology was examined. The mean evaporative loss rate was significantly higher in the PP4 group (4.75 +/- 0.24 mL/kg per h) than in either the PFD (1.43 +/- 0.11 mL/kg per h) or the PFB (1.18 +/- 0.05 mL/kg per h) group (P < 0.05). The oxygenation of PFD and PFB was maintained good for 4 h, however, the PP4 group showed a fast deterioration since 2 h post-treatment due to fast dropping of the residual PP4 amount in lungs. Histology showed good alveolar integrity in the PFD and PFB groups. The effects of PLV are directly influenced by the evaporative property of the PFC liquid. With no replacement over 4 h, PLV effects could be maintained with utilizing a PFC liquid with low, rather than high, vapor pressure. PFC with high vapor pressure has a high loss rate and low residual volume that causes poor maintenance on oxygenation during PLV. Therefore, measuring PFC loss rate is important in future studies and clinical application of PLV.Keywords
This publication has 25 references indexed in Scilit:
- Perfluorochemical (PFC) Combinations for Acute Lung Injury: An In Vitro and In Vivo Study in Juvenile RabbitsPediatric Research, 2003
- Physicochemical properties of perfluorochemical liquids influence ventilatory requirements, pulmonary mechanics, and microvascular permeability during partial liquid ventilation following intestinal ischemia/reperfusion injury*Critical Care Medicine, 2002
- A randomised control study of partial liquid ventilation after airway lavage with exogenous surfactant in a meconium aspiration syndrome animal modelArchives of Disease in Childhood - Fetal and Neonatal Edition, 2000
- Partial Liquid Ventilation in Adult Patients With ARDSAnnals of Surgery, 1998
- Partial Liquid Ventilation Combined with Inhaled Nitric Oxide in Acute Respiratory Failure with Pulmonary Hypertension in PigletsPediatric Research, 1997
- Partial Liquid Ventilation with Perflubron in Premature Infants with Severe Respiratory Distress SyndromeNew England Journal of Medicine, 1996
- Utility of a Perfluorochemical Liquid for Pulmonary Diagnostic ImagingArtificial Cells, Blood Substitutes, and Biotechnology, 1994
- Liquid ventilation of human preterm neonatesThe Journal of Pediatrics, 1990
- Perfluorocarbon blood substitutesCritical Reviews in Oncology/Hematology, 1987
- Reassessment of Criteria for the Selection of Perfluorochemicals for Second‐Generation Blood Substitutes: Analysis of Structure/Property RelationshipsArtificial Organs, 1984