Clot waveform analysis (CWA) is a recently developed global coagulation assessment, based on the continuous observation of changes in light transmittance, absorbance, or light scattering that occurs as fibrin formed in a plasma sample during routine clotting tests such as activated partial thromboplastin time (aPTT) and prothrombin time (PT). CWA can utilize qualitative waveform patterns as well as sensitive quantitative parameters and can be used as a simple method to assess global hemostasis, and can be applied to various challenging clinical situations. Although not all coagulation analyzers currently in use are able to provide CWA, the number of analyzers available to do so is increasing, as the usefulness of this process has become more widely recognized. CWA can be based on the coagulation mechanism of aPTT, an intrinsic trigger, and this has been reported in many studies, including diagnosis and treatment of patients with hemophilia, disseminated intravascular coagulation, and monitoring of anticoagulants and thrombosis. CWA using trace amounts of tissue factors also has the potential to expand the applications of this technology. Recently, there have been reports of the combined evaluation of fibrinolytic dynamics. Among the existing global coagulation assays, CWA may prove to be the easiest to standardize in clinical practice. However, more extensive testing using standardized methods in various clinical settings is needed to determine the true role of CWA in the evaluation of hemostasis and thrombosis in the future.Keywords
This publication has 53 references indexed in Scilit:
- Identification and Multidimensional Optimization of an Asymmetric Bispecific IgG Antibody Mimicking the Function of Factor VIII Cofactor ActivityPLOS ONE, 2013
- The mild phenotype in severe hemophilia A with Arg1781His mutation is associated with enhanced binding affinity of factor VIII for factor XThrombosis and Haemostasis, 2013
- Results of clot waveform analysis and thrombin generation test for a plasma‐derived factor VIIa and X mixture (MC710) in haemophilia patients with inhibitors—phase I trial: 2nd reportHaemophilia, 2012
- Demographic and clinical data in acquired hemophilia A: results from the European Acquired Haemophilia Registry (EACH2)Journal of Thrombosis and Haemostasis, 2012
- New assays for monitoring haemophilia treatmentHaemophilia, 2008
- Thrombin generation, fibrin clot formation and hemostasisTransfusion and Apheresis Science, 2008
- Phenotypic heterogeneity in severe hemophiliaJournal of Thrombosis and Haemostasis, 2007
- The measurement of low levels of factor VIII or factor IX in hemophilia A and hemophilia B plasma by clot waveform analysis and thrombin generation assayJournal of Thrombosis and Haemostasis, 2006
- Effectiveness of factor VIII infusions in haemophilia A patients with high responding inhibitorsHaemophilia, 2004
- Biphasic transmittance waveform in the APTT coagulation assay is due to the formation of a Ca++-dependent complex of C-reactive protein with very-low–density lipoprotein and is a novel marker of impending disseminated intravascular coagulationBlood, 2002