Measurement of Spontaneous Oscillatory Magnetic Field of Guinea-Pig Smooth Muscle Preparation Using Pico-Tesla Resolution Amorphous Wire Magneto-Impedance Sensor
Authors:
- 26 September 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 47 (10) , 3070-3073
Abstract
New measured results of spontaneous oscillatory bio-magnetic field generated from preparations of guinea-pig smooth muscle tissue are presented in this paper using the pico-Tesla MI sensor. It is confirmed that the changes in the bio-magnetic field activity precisely synchronized with extracellular electric activity for stomach musculature of the guinea-pig. It is, however, noteworthy that these two activities provide different biological information. A phase lag of around 2 s of the magnetic signal pulse against the extracellular electric signal pulse is newly found. It is also shown that Ca2+ channel activity of the smooth muscle tissue (taenia caeci) can be evaluated using the MI sensor. Both electric and magnetic activities depend on the functionality of the living tissues. Therefore, the pico-Tesla MI sensor has the potential for non-invasive detection use in wide range of biology and medicine, including non-invasive evaluation use of the stem cells development.Keywords
This publication has 9 references indexed in Scilit:
- Biomagnetic field detection using very high sensitivity magnetoimpedance sensors for medical applicationsPhysica Status Solidi (a), 2009
- Optimization of the magnetic noise and sensitivity of giant magnetoimpedance sensorsJournal of Applied Physics, 2008
- Amorphous Wire and CMOS IC Based Magneto-Impedance Sensors—Origin, Topics, and FutureSensor Letters, 2007
- Pacemaker phase shift in the absence of neural activity in guinea‐pig stomach: a microelectrode array studyThe Journal of Physiology, 2006
- Action potential refractory period in ureter smooth muscle is set by Ca sparks and BK channelsNature, 2005
- Off-Diagonal Impedance in Amorphous Wires and Its Application to Linear Magnetic SensorsIEEE Transactions on Magnetics, 2004
- Highly stable MI micro sensor using CMOS IC multivibrator with synchronous rectification [for automobile control application]IEEE Transactions on Magnetics, 1999
- Magneto-impedance effect in amorphous wiresApplied Physics Letters, 1994
- Effects of stimulating the acetylcholine receptor on the current‐voltage relationships of the smooth muscle membrane studied by voltage clamp of potential recorded by micro‐electrode.The Journal of Physiology, 1975