Abstract
Real‐time Raman measurements have been performed on Si(111) under Ar+ ion irradiation with a time resolution of 15 s. Ion flux of 3×1011 ions cm−2 s−1 and ion energy of 3 and 5 keV are used. Decrease in the intensity of the TO line (at 521 cm−1) has been observed as irradiation time increases. The reduction rate of 5‐keV irradiation is larger than that of 3‐keV irradiation.