LOCS III versus the Oxford Clinical Cataract Classification and Grading System for the assessment of nuclear, cortical and posterior subcapsular cataract
Authors:
- 1 January 1997
- journal article
- research article
- Published by Taylor & Francis in Ophthalmic Epidemiology
- Vol. 4 (4) , 179-194
Abstract
Purpose To compare two methods of cataract grading for nuclear cataract, cortical cataract and posterior subcapsular cataract. Methods The Melton Eye Study is an English community-based epidemiological study of the natural history of eye disease in people aged 55 to 74 years. The lenses of both eyes of 560 subjects were graded at the slit lamp using two cataract grading systems. The Oxford Clinical Cataract Classification and Grading System (OCCCGS) employs standard diagrams and Munsell colour samples for the grading of cortical, posterior subcapsular and nuclear cataract. The Lens Opacities Classification System III (LOCS III) uses photographic transparencies of the lens as standards. In both systems a decimalised score is assigned. We also graded the LOCS III standard images using the OCCCGS. Interobserver variation was calculated for both grading systems. Linear calibration lines are plotted for each type of lens opacity. Results The relationship between LOCS III and OCCCGS for nuclear cataract and posterior subcapsular cataract is linear. The relationship for cortical cataract is linear once the LOCS III scores are squared. The intervals between the LOCS in images when ranked by the human eye using the OCCCGS are linear. Interobserver variation for both systems is good. Conclusions The linear calibration lines may be used to convert from one system to another and will be useful in comparing studies or performing meta-analysis. These results show that data from cataract studies using different clinical grading schemes can be compared.Keywords
This publication has 12 references indexed in Scilit:
- Quantitative analysis of retroillumination imagesEye, 1995
- Evaluation of Lens Opacities Classification System III Applied at the SlitlampOptometry and Vision Science, 1993
- Development of a Scheimpflug slit lamp camera system for quantitative densitometric analysisEye, 1993
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993
- Assessment of Cataracts from Photographs in the Beaver Dam Eye StudyOphthalmology, 1990
- The Oxford modular cataract image analysis systemEye, 1990
- Lens Opacities Classification System II (LOCS II)Archives of Ophthalmology (1950), 1989
- Inter-observer and intra-observer variability of the Oxford clinical cataract classification and grading systemInternational Ophthalmology, 1988
- The Oxford Clinical Cataract Classification and Grading SystemInternational Ophthalmology, 1986
- The detection and grading of cataract: An epidemiologic perspectiveSurvey of Ophthalmology, 1986