Stability of the LMA-ProSeal® and standard laryngeal mask airway in different head and neck positions: a randomized crossover study
Authors:
- J. BrimacombeJBJ. Brimacombe
- C. KellerCKC. Keller
- 1 January 2003
- journal article
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 20 (1) , 65-69
Abstract
The LMA-ProSeal® laryngeal mask airway is a new laryngeal mask airway with a modified cuff and drainage tube. We compared oropharyngeal leak pressure, intracuff pressure and anatomical position (assessed fibreoptically) for the Size 5 LMA-ProSeal® laryngeal mask airway and the classic laryngeal mask airway in different head-neck positions and using different intracuff inflation volumes. Thirty paralysed anaesthetized adult male patients were studied. The LMA-ProSeal® laryngeal mask airway and the classic laryngeal mask airway were inserted into each patient in random order. The oropharyngeal leak pressure, intracuff pressure, and anatomical position of the airway tube and drainage tube (LMA-ProSeal® laryngeal mask airway only) were documented in four head and neck positions (neutral first, then flexion, extension and rotation in random order), and at 0-40 mL cuff volumes in the neutral position in 10 mL increments. Compared with the neutral position, the oropharyngeal leak pressure for both the LMA-ProSeal® laryngeal mask airway and the classic laryngeal mask airway was higher in flexion and rotation (all P ≤ 0.02), but lower in extension (all P ≤ 0.01). Changes in head-neck position did not alter the anatomical position of the airway tube or the drainage tube. The oropharyngeal leak pressure was always higher for the LMA-ProSeal® laryngeal mask airway (all P ≤ 0.005) and anatomical position better for the classic laryngeal mask airway (all P ≤ 0.04). The anatomical position of the LMA-ProSeal® and the classic laryngeal mask airway is stable in different head-neck positions, but head-neck flexion and rotation are associated with an increase, and head-neck extension a decrease, in oropharyngeal leak pressure and intracuff pressure. The Size 5 LMA-ProSeal® laryngeal mask airway is capable of forming a more effective seal than the Size 5 classic laryngeal mask airway in males.Keywords
This publication has 6 references indexed in Scilit:
- The LMA ‘ProSeal’—a laryngeal mask with an oesophageal ventBritish Journal of Anaesthesia, 2000
- A Comparison of the Reinforced and Standard Laryngeal Mask Airway: Ease of Insertion and the Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Intracuff PressureAnaesthesia and Intensive Care, 1999
- The Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the Flexible and the Standard Laryngeal Mask AirwayAnesthesia & Analgesia, 1999
- Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patientsBritish Journal of Anaesthesia, 1999
- An evaluation of the factors influencing selection of the optimal size of laryngeal mask airway in normal adultsAnaesthesia, 1998
- The laryngeal mask airwayAnaesthesia, 1991