The Delineation of Fiducial Points for Non-Contact Radar Seismocardiogram Signals Without Concurrent ECG
- 17 July 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (4) , 1031-1040
Abstract
Objective: Non-contact sensing of seismocardiogram (SCG) signals through a microwave Doppler radar is promising for biomedical applications. However, the delineation of fiducial points for radar SCG still relies on concurrent ECG which requires a contact sensor and limits the complete non-contact detection of SCG. Methods: Instead of ECG, a new reference signal, the radar displacement signal of heartbeat (RDH), was derived through the complex Fourier transform and the band pass filtering of the radar signal. The RDH signal was used to locate each cardiac cycle and mask the systolic profile, which was further used to detect an important fiducial point, aortic valve opening (AO). The beat-to-beat interval was estimated from AO-AO interval and compared with the gold standard, ECG R-to-R interval. Results: For the 22 subjects in the study, the evaluation of the AOs detected by RDH (AORDH) shows the average detection ratio can reach 90%, indicating a high ratio of the AORDH that are exactly the same as AO detected using the ECG R-wave (AOECG). Additionally, the left ventricular ejection time (LVET) values estimated from the ensemble averaged radar waveform through AORDH segmentation are within 2 ms of those through AOECG segmentation, for all the detected subjects. Further analysis demonstrates that the beat-to-beat intervals calculated from AORDH have an average root-mean-square-deviation (RMSD) of 53.73 ms when compared with ECG R-to-R intervals, and have an average RMSD of 23.47 ms after removing the beats in which AO cannot be identified. Conclusions: Radar signal RDH can be used as a reference signal to delineate fiducial points for non-contact radar SCG signals. Significance: This study can be applied to develop complete non-contact sensing of SCG and monitoring of vital signs, where contact-based SCG is not feasibleKeywords
This publication has 28 references indexed in Scilit:
- Systolic Time Intervals and New Measurement MethodsCardiovascular Engineering and Technology, 2016
- Moving toward automatic and standalone delineation of seismocardiogram signal2015
- Ballistocardiography and Seismocardiography: A Review of Recent AdvancesIEEE Journal of Biomedical and Health Informatics, 2014
- Automatic Annotation of Seismocardiogram With High-Frequency Precordial AccelerationsIEEE Journal of Biomedical and Health Informatics, 2014
- Precordial Vibrations Provide Noninvasive Detection of Early-Stage HemorrhageShock, 2014
- Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometerPhysiological Measurement, 2012
- Effect size, confidence interval and statistical significance: a practical guide for biologistsBiological Reviews, 2007
- Seismocardiography for Monitoring Changes in Left Ventricular Function during IschemiaChest, 1991
- Confidence intervals rather than P values: estimation rather than hypothesis testing.BMJ, 1986
- A critical review of the systolic time intervals.Circulation, 1977