Repeated spurious elevation of serum prostate-specific antigen values solved by chemiluminescence analysis: A possible interference by heterophilic antibodies
Open Access
- 1 January 2015
- journal article
- case report
- Published by The Korean Urological Association in Korean Journal of Urology
- Vol. 56 (11) , 785-787
Abstract
Domínguez A, et al. Korean J Urol. 2015 Nov;56(11):785-787. http://dx.doi.org/10.4111/kju.2015.56.11.785Keywords
This publication has 12 references indexed in Scilit:
- Artificial Prostate-Specific Antigen Persistence After Radical ProstatectomyJournal of Clinical Oncology, 2012
- New onset of heterophilic antibody interference in prostate-specific antigen measurement occurring during the period of post-prostatectomy prostate-specific antigen monitoringAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2009
- Inappropriate treatment of prostate cancer caused by heterophilic antibody interferenceNature Reviews Urology, 2009
- Spurious prostate-specific antigen (PSA) recurrence after radical prostatectomy: Interference by human antimouse heterophile antibodiesInternational Journal of Urology, 2006
- False elevations in prostate-specific antigen levels affecting patient management.2004
- Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassaysClinica Chimica Acta, 2002
- Falsely increased prostate-specific antigen concentration attributed to heterophilic antibodiesAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2002
- Serum heterophile antibodies interfere with prostate specific antigen test and result in over treatment in a patient with prostate cancer.2001
- SERUM HETEROPHILE ANTIBODIES INTERFERE WITH PROSTATE SPECIFIC ANTIGEN TEST AND RESULT IN OVER TREATMENT IN A PATIENT WITH PROSTATE CANCERJournal of Urology, 2001
- Endogenous interference in imunoassays in clinical chemistry. A rewievScandinavian Journal of Clinical and Laboratory Investigation, 1990