Light Distribution Photometry in Japan
Author:
- Y. KuriokaYKY. Kurioka
- 1 December 1971
- journal article
- Published by Optica Publishing Group in Applied Optics
- Vol. 10 (12) , 2600-2606
Abstract
Of the representative distribution photometers constructed in Japan, a large-size photometer without mirrors, a compensation method for the variation in light output of a lamp, and an automatic recording of a sinusoidal isocandela diagram are illustrated. Next, a new idea for integrating the luminous flux of a lamp proposed by Ishii and Muroi and a photometer based on it are explained. The error due to two kinds of light distribution from light sources in the sphere photometer using a light distribution photometer are discussed. Finally, a theory is introduced on the photometric error due to the error in positioning the light source in the light distribution photometer. Application of the theory shows that the error in luminous flux is negligible if reasonable care is taken in positioning the lamp.Keywords
This publication has 5 references indexed in Scilit:
- Report on the Results of Comparison of the Photometric Methods for Lighting Equipment in JapanJournal of the Illuminating Engineering Institute of Japan, 1968
- Automatic Light Distribution Measuring EquipmentJournal of the Illuminating Engineering Institute of Japan, 1966
- Photometric Errors due to Setting Errors for Light Sources On the Light Distribution PhotometerJournal of the Illuminating Engineering Institute of Japan, 1965
- Automatic Hight Distribution Measuring Deviceat Electrotechnical LoboratoryJournal of the Illuminating Engineering Institute of Japan, 1964
- Some Problems on the Photometry of High Pressure Mercury LampsJournal of the Illuminating Engineering Institute of Japan, 1960