Comparison of cardiac output determined by different rebreathing methods at rest and at peak exercise
- 11 December 2007
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 102 (5) , 593-599
Abstract
Several rebreathing methods are available for cardiac output (Q T) measurement. The aims of this study were threefold: first, to compare values for resting Q T produced by the equilibrium-CO2, exponential-CO2 and inert gas-N2O rebreathing methods and, second, to evaluate the reproducibility of these three methods at rest. The third aim was to assess the agreement between estimates of peak exercise Q T derived from the exponential and inert gas rebreathing methods. A total of 18 healthy subjects visited the exercise laboratory on different days. Repeated measures of Q T, measured in a seated position, were separated by a 5 min rest period. Twelve participants performed an incremental exercise test to determine peak oxygen consumption. Two more exercise tests were used to measure Q T at peak exercise using the exponential and inert gas rebreathing methods. The exponential method produced significantly higher estimates at rest (averaging 10.9 l min−1) compared with the equilibrium method (averaging 6.6 l min−1) and the inert gas rebreathing method (averaging 5.1 l min−1; P < 0.01). All methods were highly reproducible with the exponential method having the largest coefficient of variation (5.3%). At peak exercise, there were non-significant differences between the exponential and inert gas rebreathing methods (P = 0.14). The limits of agreement were −0.49 to 0.79 l min−1. Due to the ability to evaluate the degree of gas mixing and to estimate intra-pulmonary shunt, we believe that the inert gas rebreathing method has the potential to measure Q T more precisely than either of the CO2 rebreathing methods used in this study. At peak exercise, the exponential and inert gas rebreathing methods both showed acceptable limits of agreement.Keywords
This publication has 29 references indexed in Scilit:
- Noninvasive Measurement of Cardiac Output During Exercise by Inert Gas Rebreathing Technique: A New Tool for Heart Failure EvaluationJACC, 2005
- Effects of ventilation on cardiac output determined by inert gas rebreathingClinical Physiology and Functional Imaging, 2005
- Partial carbon dioxide rebreathingCritical Care Medicine, 1997
- Carbon dioxide rebreathing method of cardiac output measurement during acute respiratory failure in patients with chronic obstructive pulmonary diseaseCritical Care Medicine, 1994
- A NON-INVASIVE METHOD FOR MEASURING CARDIAC OUTPUT: THE EFFECT OF CHRISTMAS LUNCHThe Lancet, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Measurement of mixed venous carbon dioxide pressure by rebreathing during exerciseRespiration Physiology, 1985
- Evaluation of the CO2 rebreathing cardiac output method in seriously ill patients.Circulation, 1977
- Maximal oxygen intake and nomographic assessment of functional aerobic impairment in cardiovascular diseaseAmerican Heart Journal, 1973
- The Reproducibility of Cardiac Output Determination by the Direct Fick Method During Muscular WorkScandinavian Journal of Clinical and Laboratory Investigation, 1960