Sequencing wasp venom peptides by endopeptidase digestion and nested collision‐induced dissociation/post‐source decay methods
- 18 April 2002
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (11) , 1040-1048
Abstract
A method incorporating nested collision‐induced dissociation/post‐source decay (CID/PSD) combined with endopeptidase digestion is described as an approach to determine the sequence of N‐terminally modified peptides. The information from immonium and related ions observed in the CID/PSD spectrum was used for the selection of a suitable endopeptidase for the digestion of peptides. Rapid and reliable assignment of peptide sequence was performed by the comparison of CID/PSD spectra of both intact and endopeptidese‐digested peptide fragments, since the assignments of the observed fragment ions to either N‐ or C‐terminal ions can thus be carried out unambiguously. This nested CID/PSD method was applied to the sequence determination of two peptides from the solitary wasps Anoplius samariensis and Batozonellus maculifrons (pompilid wasps), which could not be sequenced by the Edman method due to N‐terminal modification. Copyright © 2002 John Wiley & Sons, Ltd.Keywords
This publication has 28 references indexed in Scilit:
- Peer Reviewed: The New Time-of-Flight Mass Spectrometry.Analytical Chemistry, 1999
- A strategy for rapid and efficient sequencing of Lys-C peptides by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry post-source decayRapid Communications in Mass Spectrometry, 1999
- Isolation and Structure of Pompilidotoxins, Novel Peptide Neurotoxins in Solitary Wasp VenomsBiochemical and Biophysical Research Communications, 1998
- Peer Reviewed: MALDI MS and Strategies for Protein AnalysisAnalytical Chemistry, 1997
- C-Terminal Sequence Analysis of Peptides and Proteins Using Carboxypeptidases and Mass Spectrometry after Derivatization of Lys and Cys ResiduesAnalytical Chemistry, 1997
- C‐Terminal Ladder Sequencing by an Approach Combining Chemical Degradation with Analysis by Matrix‐Assisted‐Laser‐Desorption Ionization Mass SpectrometryEuropean Journal of Biochemistry, 1997
- C-Terminal Ladder Sequencing via Matrix-Assisted Laser Desorption Mass Spectrometry Coupled with Carboxypeptidase Y Time-Dependent and Concentration-Dependent DigestionsAnalytical Chemistry, 1995
- Simplified High-Sensitivity Sequencing of a Major Histocompatibility Complex Class I-Associated Immunoreactive Peptide Using Matrix-Assisted Laser Desorption/Ionization Mass SpectrometryAnalytical Biochemistry, 1995
- MALDI‐MS for C‐terminal sequence determination of peptides and proteins degraded by carboxypeptidase Y and PFEBS Letters, 1995
- Bradykinin-potentiating peptides from the venom of Agkistrodon halys. Isolation of five bradykinin potentiators and the amino acid sequences of two of them, potentiators B and CBiochemistry, 1971