A Voltage Regulation System for Independent Load Operation of Stand Alone Self-Excited Induction Generators
Authors:
- Selami KeslerSKSelami Kesler
- Tayyip L. DoserTDTayyip L. Doser
- 20 September 2016
- journal article
- Published by The Korean Institute of Power Electronics in Journal of Power Electronics
- Vol. 16 (5) , 1869-1883
Abstract
A Voltage Regulation System for Independent Load Operation of Stand Alone Self-Excited Induction Generators Fuzzy logic;Independent load operation;Separated electronic load controller;Stand-alone induction generators;Voltage regulation; In recent years, some converter structures and analyzing methods for the voltage regulation of stand-alone self-excited induction generators (SEIGs) have been introduced. However, all of them are concerned with the three-phase voltage control of three-phase SEIGs or the single-phase voltage control of single-phase SEIGs for the operation of these machines under balanced load conditions. In this paper, each phase voltage is controlled separately through separated converters, which consist of a full-bridge diode rectifier and one-IGBT. For this purpose, the principle of the electronic load controllers supported by fuzzy logic is employed in the two-different proposed converter structures. While changing single phase consumer loads that are independent from each other, the output voltages of the generator are controlled independently by three-number of separated electronic load controllers (SELCs) in two different mode operations. The aim is to obtain a rated power from the SEIG via the switching of the dump loads to be the complement of consumer load variations. The transient and steady state behaviors of the whole system are investigated by simulation studies from the point of getting the design parameters, and experiments are carried out for validation of the results. The results illustrate that the proposed SELC system is capable of coping with independent consumer load variations to keep output voltage at a desired value for each phase. It is also available for unbalanced consumer load conditions. In addition, it is concluded that the proposed converter without a filter capacitor has less harmonics on the currents.Keywords
This publication has 30 references indexed in Scilit:
- Capacitors Required for Maximum Power of a Self-Excited Single-Phase Induction Generator Using a Three-Phase MachineIEEE Transactions on Energy Conversion, 2008
- Self-excited induction generator research—a surveyElectric Power Systems Research, 2004
- Effects of long-shunt and short-shunt connections on voltage variations of a self-excited induction generatorIEEE Transactions on Energy Conversion, 1997
- A doubly fed induction generator usingback-to-back PWM converterssupplying an isolated load from a variable speed wind turbineIEE Proceedings - Electric Power Applications, 1996
- Selection of capacitors for the self regulated short shunt self excited induction generatorIEEE Transactions on Energy Conversion, 1995
- INDUCTION GENERATORS-A PROSPECTIVEElectric Machines & Power Systems, 1995
- Voltage compensation of an induction generator with long-shunt connectionIEEE Transactions on Energy Conversion, 1989
- Steady-state and transient analysis of self-excited induction generatorsIEE Proceedings B Electric Power Applications, 1989
- Simulation of Symmetrical Induction MachineryIEEE Transactions on Power Apparatus and Systems, 1965
- Capacitive excitation for induction generatorsElectrical Engineering, 1935