A data acquisition sub-system for distributed, digital, computational, APD-based, bimodal PET/CT architecture for small animal imaging
Authors:
- 1 January 2003
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 41 (10823654) , 1733-1737 Vol.3
Abstract
The integration of a positron emission tomography (PET) scanner and a computed tomography (CT) scanner using the same detection system is a real challenge. The goal of the proposed PET/CT scanner design is to achieve high-speed data acquisition with a coincidence time window smaller than 10 ns and less than 1 mm spatial resolution in both PET and CT imaging using the same PET detectors and electronics. Events can be processed at high count-rate, based on a distributed computational architecture mounted directly within the PET ring. To satisfy these new technological requirements, a modular data acquisition sub-system (DASS) was designed, capable of handling up to 64 individual PET/CT detector channels. The DASS is based on off-the-shelf 8-bit, 100-MHz, high-speed free running analog-to-digital converters (ADC) and digital signal processing running on field programmable gate arrays (FPGA). The core of the processing units consists of four Xilinx Spartan-III FPGAs that can hold up to 16 individual channels each. The modular printed circuit board (PCB) has twelve copper layers, allowing separate ground and power planes to be implemented. The PCB outline allows various configurations in a multi-ring stacking geometry to realize 3-D scanners.Keywords
This publication has 18 references indexed in Scilit:
- Dose reductions in dental X-ray imaging using MedipixNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Design and performance of 0.18-/spl mu/m CMOS charge preamplifiers for APD-based PET scanners2003
- CT acquisition using PET detectors and electronics2003
- Time determination of BGO-APD detectors by digital signal processing for positron emission tomography2003
- Simultaneous molecular and anatomical imaging of the mousein vivoPhysics in Medicine & Biology, 2002
- A modular VME or IBM PC based data acquisition system for multi-modality PET/CT scanners of different sizes and detector types2002
- Features of the NIH atlas small animal PET scanner and its use with a coaxial small animal volume CT scanner2002
- A novel APD-based detector module for multi-modality PET/SPECT/CT scannersIEEE Transactions on Nuclear Science, 1999
- Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodesIEEE Transactions on Nuclear Science, 1999
- A CMOS detector leakage current self-adaptable continuous reset system: Theoretical analysisNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999