Clinical Outcomes following Large Vessel Coronary Artery Perforation Treated with Covered Stent Implantation: Comparison between Polytetrafluoroethylene- and Polyurethane-Covered Stents (CRACK-II Registry)
Authors:
- Jerzy BartuśJBJerzy Bartuś
- Rafał JanuszekRafał Januszek
- Damian HudziakDHDamian Hudziak
- Michalina KołodziejczakMichalina Kołodziejczak
- Łukasz KuźmaŁKŁukasz Kuźma
- Mateusz TajstraMTMateusz Tajstra
- Tomasz FigatowskiTFTomasz Figatowski
- Tomasz PawłowskiTPTomasz Pawłowski
- Monika Gruz-KwapiszMGMonika Gruz-Kwapisz
- Malwina Smolarek-NicpońMSMalwina Smolarek-Nicpoń
- Agnieszka SkoczyńskaASAgnieszka Skoczyńska
- Brunon TomasiewiczBTBrunon Tomasiewicz
Open Access
- 21 November 2021
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (22) , 5441
Abstract
Data on the clinical outcomes comparing synthetic fluorocarbon polymer polytetrafluoroethylene- (PTFE, GraftMaster) and polyurethane- (Papyrus) covered stents (CSs) to seal coronary artery perforations (CAPs) are limited. We aimed to evaluate 30-day and 1-year clinical outcomes after PCI complicated by CAP and treated with CS. We assessed 106 consecutive patients with successful CAP sealing (122 CSs): GraftMaster (51 patients, 57 CSs) or Papyrus CS (55 patients, 65 CSs). The primary endpoint was the occurrence of major adverse cardiac events (MACE), defined as the composite of cardiac death, target lesion revascularisation (TLR), and myocardial infarction (MI). The mean age of subjects was 69 ± 9.6 years (53.8% males). No significant differences were identified between the GraftMaster and Papyrus groups at the 30-day follow-up for MACE, cardiac death, MI and stent thrombosis (ST), while significantly lower rate of TLR and TVR (p = 0.02) were confirmed in the Papyrus group. At one year, differences remained similar between stents for MACE, a trend towards a lower rate of TLR (p = 0.07), MI (p = 0.08), and ST (p = 0.08), and higher for cardiac death (p = 0.07) was observed in the Papyrus group. This real-life registry of CAP illustrated that the use of Papyrus CS is associated with lower rates of TLR and TVR at 30-day follow-up in comparison to the GraftMaster CSs and no significant differences between both assessed CS at one year of follow-up.Keywords
This publication has 21 references indexed in Scilit:
- Serial endovascular assessment of polytetrafluoroethylene-covered stent: Capabilities and limitations of intravascular imaging modalities affected by a temporal factorJournal of Cardiology Cases, 2015
- Coronary Artery Perforation During Percutaneous Coronary Intervention: A Systematic Review and Meta-analysisCanadian Journal of Cardiology, 2011
- 5-Year Follow-Up of Polytetrafluoroethylene-Covered Stents Compared With Bare-Metal Stents in Aortocoronary Saphenous Vein GraftsJACC: Cardiovascular Interventions, 2011
- Stent Parameters Predict Major Adverse Clinical Events and the Response to Platelet Glycoprotein IIb/IIIa BlockadeCirculation: Cardiovascular Interventions, 2009
- Delayed Endothelialization After Polytetrafluoroethylene-Covered Stent Implantation for Coronary AneurysmCirculation Journal, 2009
- Clinical End Points in Coronary Stent TrialsCirculation, 2007
- Clinical and angiographic follow-up after overlapping implantation of polytetrafluoroethylene covered stents with drug eluting stents.2006
- Results of the Jostent coronary stent graft implantation in various clinical settings: Procedural and follow‐up resultsCatheterization and Cardiovascular Interventions, 2002
- Increased coronary perforation in the new device era. Incidence, classification, management, and outcome.Circulation, 1994
- Guidelines for percutaneous transluminal coronary angioplasty. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures (Subcommittee on Percutaneous Transluminal Coronary Angioplasty).Circulation, 1988