Sensitive Voltammetric Sensor Based on Boron‐Doped Diamond Electrode for Determination of the Chemotherapeutic Drug Methotrexate in Pharmaceutical and Biological Samples
- 2 September 2014
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 27 (1) , 42-51
Abstract
A novel sensitive voltammetric method for the determination of an important chemotherapeutic drug, methotrexate, was designed using a bare boron‐doped diamond electrode in connection with differential pulse voltammetry. Methotrexate provided one well developed oxidation peak suitable for analytical purposes at about +1000 mV (vs. Ag/AgCl electrode) in an acidic medium. The voltammetric behavior of methotrexate in dependence of pH of the supporting electrolyte and scan rate has been investigated using cyclic voltammetry and DC voltammetry, respectively, to select the suitable experimental parameters. The optimum conditions for its determination using differential pulse voltammetry have been found to be 0.05 mol L−1 H2SO4 with a limit of detection of 1.0×10−8 mol L−1 and a linear dynamic range from 5×10−8 to 2×10−5 mol L−1. Calculated values of relative standard deviations of repeated determinations (n≥5) in various concentration levels of methotrexate did not exceed 4 %. The influence of possible interfering agents was studied as well. Finally, practical applicability of the newly proposed method was verified by analysis of real drug preparations and spiked human urine. The calculated recovery values ranged from 99.2 to 101.4 %.Keywords
This publication has 44 references indexed in Scilit:
- A validated LC–MS/MS method for rapid determination of methotrexate in human saliva and its application to an excretion evaluation studyJournal of Chromatography B, 2013
- Determination of methotrexate and folic acid by ion chromatography with electrochemical detection on a functionalized multi-wall carbon nanotube modified electrodeJournal of Chromatography A, 2013
- Determination of erythrocyte methotrexate polyglutamates by liquid chromatography/tandem mass spectrometry after low-dose methotrexate therapy in Chinese patients with rheumatoid arthritisJournal of Chromatography B, 2012
- Determination of methotrexate and indomethacin in urine using SPE-LC-DAD after derivatizationJournal of Pharmaceutical and Biomedical Analysis, 2011
- DNA Langmuir–Blodgett modified glassy carbon electrode as voltammetric sensor for determinate of methotrexateElectrochimica Acta, 2009
- Voltammetric determination of aminobiphenyls at a boron-doped nanocrystalline diamond film electrodeTalanta, 2007
- Methotrexate determination in pharmaceuticals by enantioselective HPLCJournal of Pharmaceutical and Biomedical Analysis, 2005
- Phase-selective alternating current polarographic assay of methotrexate in human serumAnalytica Chimica Acta, 1990
- Determination of methotrexate in human blood plasma by adsorptive stripping voltammetryTalanta, 1988
- Adsorptive cathodic stripping voltammetry of amethopterine at a static mercury drop electrode and its application to serum drug determinationThe Analyst, 1988