Gaining Improved Chemical Composition by Exploitation of Compton-to-Rayleigh Intensity Ratio in XRF Analysis
- 20 June 2014
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 86 (14) , 6858-6864
Abstract
The high specificity of the coherent (Rayleigh), as well as incoherent (Compton) X-ray scattering to the mean atomic number of a specimen to be analyzed by X-ray fluorescence (XRF), is exploited to gain more information on the chemical composition. Concretely, the evaluation of the Compton-to-Rayleigh intensity ratio from XRF spectra and its relation to the average atomic number of reference materials via a calibration curve can reveal valuable information on the elemental composition complementary to that obtained from the reference-free XRF analysis. Particularly for matrices of lower mean atomic numbers, the sensitivity of the approach is so high that it can be easily distinguished between specimens of mean atomic numbers differing from each other by 0.1. Hence, the content of light elements which are “invisible” for XRF, particularly hydrogen, or of heavier impurities/additives in light materials can be calculated “by difference” from the scattering calibration curve. The excellent agreement between such an experimental, empirical calibration curve and a synthetically generated one, on the basis of a reliable physical model for the X-ray scattering, is also demonstrated. Thus, the feasibility of the approach for given experimental conditions and particular analytical questions can be tested prior to experiments with reference materials. For the present work a microfocus X-ray source attached on an SEM/EDX (scanning electron microscopy/energy dispersive X-ray spectroscopy) system was used so that the Compton-to-Rayleigh intensity ratio could be acquired with EDX spectral data for improved analysis of the elemental composition.Keywords
This publication has 37 references indexed in Scilit:
- Simultaneous Nondestructive Analysis of Palladium, Rhodium, Platinum, and Gold Nanoparticles Using Energy Dispersive X-ray FluorescenceAnalytical Chemistry, 2013
- Three-Dimensional Chemical Mapping with a Confocal XRF SetupAnalytical Chemistry, 2013
- X-ray SpectrometryAnalytical Chemistry, 2011
- Complementary Characterization of Buried Nanolayers by Quantitative X-ray Fluorescence Spectrometry under Conventional and Grazing Incidence ConditionsAnalytical Chemistry, 2011
- X-ray fluorescence as an additional analytical method for a scanning electron microscopeMicrochimica Acta, 2007
- Integrated XRF in the SEMMicroscopy and Microanalysis, 2004
- A modular system for XRF and XRD applications consisting of a microfocus X‐ray source and different capillary opticsX-Ray Spectrometry, 2004
- Matrix corrections for energy dispersive x-ray fluorescence analysis of environmental samples with coherent/incoherent scattered x-raysAnalytical Chemistry, 1977
- Quick determination of the average atomic number by X-ray scatteringNuclear Instruments and Methods, 1972
- Scattered X-Rays as Internal Standards in X-Ray Emission SpectroscopyAnalytical Chemistry, 1958