Ultrafiltration and Clearance Studies in Human Isolated Peritoneal Vascular Loops

Authors:
  • ABAlessandra Brendolan
    Alessandra Brendolan
  • CCCarlo Crepaldi
    Carlo Crepaldi
  • PCPietro Conz
    Pietro Conz
  • LBLuisa Bragantini
    Luisa Bragantini
  • MMMassimo Milan
    Massimo Milan
  • GGGiuseppe La Greca
    Giuseppe La Greca

Abstract
Eight samples of human peritoneal tissue were obtained from patients undergoing hemicholectomy for cancer. An artery and a vein were cannulated and perfused with blood in vitro with a special circuit able to provide different perfusion pressures. Ultrafiltration and clearance studies were performed in these samples. Both ultrafiltration and small-solute clearances linearly correlated with the blood flow, demonstrating a strong dependence on this parameter. The peritoneal capillary showed a typical filtration pressure equilibrium with a constant filtration fraction at different blood flows. The results suggest that the blood flow may be a factor limiting the efficiency of peritoneal dialysis both in terms of mass transfer coefficients and maximal ultrafiltration rates.