Assessment of Surface Roughness and Waviness Using White Light Interferometry for Short-Term Implanted, Highly Crosslinked Acetabular Components
Authors:
- 1 January 2004
- book chapter
- Published by ASTM International
- p. 41-56
Abstract
The reduction of volumetric wear continues to be one of the imminent challenges for the orthopaedic research community in the area of ultra-high molecular weight polyethylene (UHMWPE) joint replacement components. Retrieval analyses are necessary to determine the relationship between in vitro hip simulator predictions and actual wear performance in vivo. To quantify short term wear in retrieved highly crosslinked acetabular components it is necessary to differentiate between the initial surface morphology (dominated by manufacturer's machining marks) and the smaller scale surface features associated with in vivo adhesive/abrasive wear mechanisms. We have developed and validated a technique for deconvolution of as-manufactured versus in vivo generated surface topology from retrieved, highly crosslinked polyethylene acetabular inserts. Surface topology was characterized by white light interferometry with advanced texture analysis software. A Fourier transform algorithm was used to deconvolve the low-frequency features (i.e., waviness) such as machining marks, from the high-frequency features (i.e., roughness). Twenty-one (21) short-term (less than 24 months) conventional and highly crosslinked retrievals from different manufacturers were evaluated in this study. The wear surfaces in the short-term retrievals were deconvolved using the cut-off frequencies from the new inserts. The frequency distribution and magnitude of the machining marks were found to be material and manufacturer specific. This study highlights the importance of quantitative techniques, such as white light interferometry for distinguishing between initial and in vivo generated surface morphology. The topology observed in the crosslinked retrievals was consistent with the surface damage mechanisms previously observed in conventional UHMWPE components, namely macroscopic and microscopic adhesive/abrasive wear.Keywords
This publication has 14 references indexed in Scilit:
- Alternate Bearing Surfaces in Hip Replacement2002
- Deconvolution of surface topology for quantification of initial wear in highly cross‐linked acetabular components for THAJournal of Biomedical Materials Research, 2002
- Mechanical behavior, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantationWear, 2001
- Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplastyBiomaterials, 1999
- The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacementJournal of Biomedical Materials Research, 1999
- Lubrication and wear of ultra-high molecular weight polyethylene in total joint replacementsTribology International, 1998
- Measurement of Polyethylene Wear in Metal-Backed Acetabular CupsClinical Orthopaedics and Related Research, 1995
- Role of cyclic plastic deformation in the wear of UHMWPE acetabular cupsJournal of Biomedical Materials Research, 1995
- Macroscopic and microscopic wear mechanisms in ultra-high molecular weight polyethyleneWear, 1993
- Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prosthesesJournal of Biomedical Materials Research, 1983