Three-point transoptical flanged IOL fixation to sclera and cornea: a case report
Open Access
- 31 March 2026
- journal article
- Published by ECO-Vector LLC (Publications) in Ophthalmology Reports
- Vol. 19 (1) , 83-90
Abstract
Late in-the-bag intraocular lens dislocation is a clinically significant complication of cataract surgery, which can develop years after initially successful phacoemulsification and lead to a marked decrease in visual function. Although various techniques of secondary intraocular lens (IOL) fixation are available, so far there is no universal minimally invasive approach ensuring high lens stability and a low risk of intraocular damage, especially in patients with no vitreous, zonular damage, and vitreoretinal history. Therefore, ophthalmic surgery requires new technical solutions to optimize posterior chamber IOL fixation in case of late dislocation. The article describes a clinical case of surgical treatment of a 66-year-old patient with late in-the-bag dislocation of a posterior chamber acrylic IOL into the vitreous 15 years after phacoemulsification. The patient had concomitant risk factors, including high myopia, previous vitrectomy for rhegmatogenous retinal detachment, and controlled open-angle glaucoma. IOL repositioning was performed followed by sutureless transoptical three-point non-collinear flanged fixation to the sclera and cornea. The technique involved suturing the periphery of the lens optic at three points to create multiple fixation vectors. In the postoperative period, uncorrected and best corrected visual acuity increased, and the IOL was stable and centered without any signs of tilt or decentration. Optical coherence tomography and ultrasound biomicroscopy confirmed correct anatomical lens position, no contact with the iris or cornea, and safe intracorneal position of the flanges. The presented clinical case demonstrates that three-point non-collinear transoptical flanged fixation can reliably stabilize the IOL in case of late dislocation and anatomical challenges. The conclusions are based on a single case and require further clinical confirmation in a larger patient population.Keywords
This publication has 18 references indexed in Scilit:
- Intracorneal knot or flange depot fixation: new transscleral technique for intraocular lens fixationJournal of Cataract & Refractive Surgery, 2022
- Late in-the-bag intraocular lens dislocationJournal of Cataract & Refractive Surgery, 2021
- A Modified Iris Suture Technique for In-the-bag Intraocular Lens DislocationRetina, 2017
- Incidence and risk factors of late in-the-bag intraocular lens dislocation: Evaluation of 140 eyes between 1992 and 2012Journal of Cataract & Refractive Surgery, 2015
- Phacoemulsification with posterior chamber intraocular lens versus extracapsular cataract extraction (ECCE) with posterior chamber intraocular lens for age-related cataractCochrane Database of Systematic Reviews, 2014
- Risk of Late Intraocular Lens Dislocation After Cataract Surgery, 1980–2009: A Population-Based StudyAmerican Journal of Ophthalmology, 2011
- Modified transscleral fixation technique for refixation of dislocated intraocular lensesJournal of Cataract & Refractive Surgery, 2008
- Posterior Iris Fixation of the Iris-Claw Intraocular Lens Implantation through a Scleral Tunnel IncisionAmerican Journal of Ophthalmology, 2007
- Small-Incision Iris Fixation of Foldable Intraocular Lenses in the Absence of Capsule SupportOphthalmology, 2007
- Tilt and decentration after primary and secondary transsclerally sutured posterior chamber intraocular lens implantationJournal of Cataract & Refractive Surgery, 2001