Abstract
The study aims to identify the main reason of the thermal response time difference between historical and modern buildings. Therefore, in this study, the thermal response time of historical and modern wall structures and its effect on the interior air temperature change was investigated parametrically. Considering the environmental conditions of Kocaeli province, Turkey, the thermal response time of a historical building wall made of a cut stone was compared with those of brick and gas concrete wall structures having the same overall heat transfer coefficient using the second-order lumped capacitance approach. The insulation thicknesses of the three different construction materials for U-values of 0.6, 0.4 and 0.2 W/m2K were calculated and temperature variations of indoor environment, wall and insulation material were analyzed. In addition, the required thicknesses of insulation material to obtain the same heat transfer coefficients were determined in case of using the 0.1 m thickness of cut stone, brick and gas concrete structure materials. The maximum and minimum amplitudes of the inside air temperature were recorded as 0.59 and 0.18oC for the aerated concrete in Case 3 and for the cut stone in Case 2, respectively. As a result, the walls with high thermal inertia are less affected by the changes in the environmental temperature although their U-value is relatively high. For this reason, it can be stated that one of the reasons why historical buildings have thick walls is to increase thermal inertia and thereby improve thermal comfort by reducing energy loss.Keywords
This publication has 34 references indexed in Scilit:
- Study of the economical and optimum thermal insulation thickness for buildings in a wet and hot tropical climate: Case of CameroonRenewable and Sustainable Energy Reviews, 2015
- Thermal inertia and energy efficiency – Parametric simulation assessment on a calibrated case studyApplied Energy, 2015
- Assessment of the dynamic thermal performance of massive buildingsEnergy and Buildings, 2014
- Extending the validity of lumped capacitance method for large Biot number in thermal storage applicationSolar Energy, 2012
- The influence of the external walls thermal inertia on the energy performance of well insulated buildingsEnergy and Buildings, 2009
- Physico-mechanical and thermal performances of newly developed rubber-added bricksEnergy and Buildings, 2008
- Determination of optimum insulation thicknesses of the external walls and roof (ceiling) for Turkey's different degree-day regionsEnergy Policy, 2007
- Building thermal model reduction using nonlinear constrained optimizationBuilding and Environment, 2002
- Convective heat transfer coefficients at a plane surface on a full-scale building facadeInternational Journal of Heat and Mass Transfer, 1996
- Thermal behaviours of vernacular buildings in the Yemen Arab RepublicApplied Energy, 1986