Is liver perfusion CT reproducible? A study on intra- and interobserver agreement of normal hepatic haemodynamic parameters obtained with two different software packages
- 26 September 2017
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 90 (1078) , 20170214
Abstract
Objective: To evaluate the agreement between the measurements of perfusion CT parameters in normal livers by using two different software packages. Methods: This retrospective study was based on 78 liver perfusion CT examinations acquired for detecting suspected liver metastasis. Patients with any morphological or functional hepatic abnormalities were excluded. The final analysis included 37 patients (59.7 ± 14.9 y). Two readers (1 and 2) independently measured perfusion parameters using different software packages from two major manufacturers (A and B). Arterial perfusion (AP) and portal perfusion (PP) were determined using the dual-input vascular one-compartmental model. Inter-reader agreement for each package and intrareader agreement between both packages were assessed with intraclass correlation coefficients (ICC) and Bland-Altman statistics. Results: Inter-reader agreement was substantial for AP using software A (ICC = 0.82) and B (ICC = 0.85–0.86), fair for PP using software A (ICC = 0.44) and fair to moderate for PP using software B (ICC = 0.56–0.77). Intrareader agreement between software A and B ranged from slight to moderate (ICC = 0.32–0.62) for readers 1 and 2 considering the AP parameters, and from fair to moderate (ICC = 0.40–0.69) for readers 1 and 2 considering the PP parameters. Conclusion: At best there was only moderate agreement between both software packages, resulting in some uncertainty and suboptimal reproducibility. Advances in knowledge: Software-dependent factors may contribute to variance in perfusion measurements, demanding further technical improvements. AP measurements seem to be the most reproducible parameter to be adopted when evaluating liver perfusion CT.Keywords
This publication has 41 references indexed in Scilit:
- Quantitative hepatic CT perfusion measurement: Comparison of Couinaud's hepatic segments with dual-source 128-slice CTEuropean Journal of Radiology, 2013
- Quantification of Variability in Breath-hold Perfusion CT of Hepatocellular Carcinoma: A Step toward Clinical UseRadiology, 2012
- Perfusion measurement of the whole upper abdomen of patients with and without liver diseases: Initial experience with 320-detector row CTEuropean Journal of Radiology, 2012
- Perfusão por tomografia computadorizada do abdome: aplicações clínicas, princípios e técnica do exameRadiologia Brasileira, 2012
- Effect of Dual Vascular Input Functions on CT Perfusion Parameter Values and Reproducibility in Liver Tumors and Normal LiverJournal of Computer Assisted Tomography, 2012
- Dynamic contrast-enhanced imaging techniques: CT and MRIBritish Journal of Radiology, 2011
- Reproducibility of Perfusion Parameters Obtained From Perfusion CT in Lung TumorsAmerican Journal of Roentgenology, 2011
- Experimental Design and Data Analysis in Receiver Operating Characteristic Studies: Lessons Learned from Reports inRadiologyfrom 1997 to 2006Radiology, 2009
- In Defense of Body CTAmerican Journal of Roentgenology, 2009
- Hepatic Perfusion Parameters in Chronic Liver DiseaseAmerican Journal of Roentgenology, 2001