Histological Methods to Determine Blood Flow Distribution with Fluorescent Microspheres
Authors:
- 1 January 1998
- journal article
- research article
- Published by Taylor & Francis in Biotechnic & Histochemistry
- Vol. 73 (6) , 291-309
Abstract
We evaluated several histological methods and determined their advantages and disadvantages for histological studies of tissues and organs perfused with fluorescent microspheres. Microspheres retained their fluorescence in 7–10 μm serial sections with a change in the antimedium from toluene when samples were fixed in formalin and embedded in paraffin. Several antimedia allowed both wax infiltration of tissue and preservation of microsphere fluorescence. Histoclear II was the best substitute for toluene. When samples were fixed in formalin and embedded in glycol methacrylate, thinner (3–5 μm) sections provided greater histological detail but had fewer microspheres per section. Air dried lung tissue followed by Vibratome sectioning provided thick sections (100 μm) that facilitated rapid survey of large volumes of tissue for microspheres but limited histological detail, and the air drying procedure was restricted to lung tissue. Samples fixed in formalin followed by Vibratome sectioning of unembedded tissue provided better histological detail of lung tissue and was also useful for other organs. These sections were more difficult to handle and to mount on slides compared to air dried tissue, whereas fixed tissue embedded in gelatin provided better tissue support for Vibratome sectioning. Rapid freezing followed by cryo-microtome sectioning resulted in frozen sections that were relatively difficult to handle compared to embedded or unembedded tissue; they also deteriorated relatively rapidly with time. Paraffin sections were stained with hematoxylin and eosin or with aqueous methyl green, although tissue autofluorescence by itself was usually sufficient to identify histological features. Methacrylate sections quenched tissue autofluorescence, and Lee's stain or Richardson's stain were used for staining sections. Toluene based mountants such as Cytoseal quenched fluorescence, particularly the red fluorescent microspheres. Aqueous based mountants such as Aquamount, Crystal/Mount, Fluoromount-G were substituted, although such preparations were not as permanent as Cytoseal mounted coverglasses and tended to cause fading of stained sections.Keywords
This publication has 19 references indexed in Scilit:
- Estimated Functional Diameter of Alveolar Septal Microvessels at the Zone I‐II BorderMicrocirculation, 1997
- Distribution of pulmonary and bronchial blood supply to airways measured by fluorescent microspheresJournal of Applied Physiology, 1996
- Vital confocal microscopy in boneScanning, 1995
- Deflection of a substrate induced by an anisotropic thin-film stressJournal of Applied Physics, 1994
- Effect of detergent on alveolar particle clearance due to large tidal ventilation.Thorax, 1994
- A Method for Detecting Visceral Malformations in Gelatin-Embedded Rat Fetuses Using an Automatic Slicing ApparatusBiotechnic & Histochemistry, 1994
- Validation of fluorescent-labeled microspheres for measurement of regional organ perfusionJournal of Applied Physiology, 1993
- Measurement of blood flow to the adrenal capsule, cortex and medulla in dogs after hemorrhage by fluorescent microspheresJournal of the Autonomic Nervous System, 1990
- Method for the Prfservation of Polystyrene Latex Beads in Tissue SectionsStain Technology, 1989
- Resident sinusoidal macrophages in the liver of the brown bullhead (Ictalurus nebulosus): An ultrastructural, functional and cytochemical studyThe Anatomical Record, 1987