The effect of plate wettability on the dispersed-phase holdup in a pulsed disc-and-doughnut solvent extraction column is presented. Teflon, nylon, and stainless steel plates have been used to simulate a change in the wetting characteristics of the plate material that can occur in an operating column due to ageing or deposits accumulating on the plate. Experimental holdup data have been measured over a range of operating conditions using a 1.0 m long glass column with an internal diameter of 72.5 mm containing alternating discs and doughnuts. The liquid-liquid system studied was tri-n-octylamine (TOA)-kerosene-water with sulphuric acid as the solute. Results show that there are noticeable changes in the characteristic velocity (determined from measured holdup) and operational regimes for the different plate materials, particularly at low pulsation intensities, when operating under dispersed aqueous conditions. Experimental holdup data from this study have also been compared to correlations from literature for predicting holdup. As none of these correlations for holdup incorporate plate wettability, a new correlation for predicting holdup has been proposed that incorporates the contact angle of the plate material to allow for changes in the wettability of the plate surface. This correlation is able to predict the holdup data from this study to within 10.5% for aqueous dispersed conditions.Keywords
This publication has 14 references indexed in Scilit:
- Dispersed phase holdup in a pulsed disc and doughnut extraction columnBrazilian Journal of Chemical Engineering, 2011
- Extraction of Caprolactam with Toluene in a Pulsed Disc and Doughnut Column—Part I: Recommendation of a Model for Hydraulic CharacteristicsSolvent Extraction and Ion Exchange, 2006
- Extraction of Caprolactam with Toluene in a Pulsed Disc and Doughnut Column—Part II: Experimental Evaluation of the Hydraulic CharacteristicsSolvent Extraction and Ion Exchange, 2006
- Solvent Extraction Principles and Practice, Revised and Expanded2004
- A Unified Correlation for the Prediction of Dispersed-Phase Hold-Up in Liquid-Liquid Extraction ColumnsIndustrial & Engineering Chemistry Research, 1995
- Wettability Effects of Plate Materials on Hydrodynamics in a Pulsed Perforated-Plate Extraction Column of Pulser Feeder TypeIndustrial & Engineering Chemistry Research, 1995
- Prediction of dispersed phase hold-up in pulsed perforated-plate extraction columnsChemical Engineering and Processing - Process Intensification, 1988
- A study on the flow characteristics in a pulsed doughnut-disc type plate extraction columnKorean Journal of Chemical Engineering, 1984
- Über die Meßmethodik zur Bestimmung grenzflächenenergetischer Größen1Zeitschrift für Physikalische Chemie, 1964
- Perforated‐Plate extraction‐column performance and wetting characteristicsAIChE Journal, 1955