Abstract
The impedance of 18650 format cylindrical lithium ion battery cells arranged in parallel using two different configurations has been measured from 100 kHz to 200 MHz using a vector network analyzer. The same configurations have also been simulated using a full-wave 3D field solver. The results indicate that a hybrid simulation approach, which was derived from measurements on a single cell and previously applied to two cells in series with satisfactory results, is equally effective in predicting the properties of parallel cell assemblies.