Abstract
We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical trial. ROM one year postoperatively was determined in 50 patients. Mean head sizes were 28 mm (MP) and 48 mm (MM). After one year, the large head MM group showed greater improvement in internal rotation (14 degrees) than the 28 mm group (seven degrees).There were no significant differences in the absolute values of postoperative internal rotation, external rotation, flexion, extension, abduction and abduction. Absolute postoperative range of motion did not differ between the two groups. The improvement in internal rotation was greater after large femoral head metal-on-metal total hip arthroplasty. It is however questionable whether this difference is clinically relevant.Keywords
This publication has 27 references indexed in Scilit:
- Do Large Heads Enhance Stability and Restore Native Anatomy in Primary Total Hip Arthroplasty?Clinical Orthopaedics and Related Research, 2011
- Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.BMC Musculoskeletal Disorders, 2010
- Do large femoral heads reduce the risks of impingement in total hip arthroplasty with optimal and non-optimal cup positioning?International Orthopaedics, 2010
- Metal-on-metal hip resurfacing arthroplasty: A review of periprosthetic biological reactionsActa Orthopaedica, 2008
- Metal-on-Metal Hip Resurfacing Compares Favorably with THA at 2 Years FollowupClinical Orthopaedics and Related Research, 2006
- Wear of Highly Crosslinked Polyethylene against Cobalt Chrome and Ceramic femoral heads2006
- Posterior versus lateral surgical approach for total hip arthroplasty in adults with osteoarthritisCochrane Database of Systematic Reviews, 2006
- Biomechanics of Large Femoral HeadsClinical Orthopaedics and Related Research, 2004
- Interobserver reliability in measuring flexion, internal rotation, and external rotation of the hip using a plurimeter.Annals of the Rheumatic Diseases, 1996
- Hip motion related to age and sexActa Orthopaedica, 1989