Linking MS1 and MS2 signals in positive and negative modes of LC-HRMS in untargeted metabolomics using the ROIMCR approach
Authors:
Open Access
- 17 August 2023
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (25) , 6213-6225
Abstract
Data-independent acquisition (DIA) mode in liquid chromatography (LC) high-resolution mass spectrometry (HRMS) has emerged as a powerful strategy in untargeted metabolomics for detecting a broad range of metabolites. However, the use of this approach also represents a challenge in the analysis of the large datasets generated. The regions of interest (ROI) multivariate curve resolution (MCR) approach can help in the identification and characterization of unknown metabolites in their mixtures by linking their MS1 and MS2 DIA spectral signals. In this study, it is proposed for the first time the analysis of MS1 and MS2 DIA signals in positive and negative electrospray ionization modes simultaneously to increase the coverage of possible metabolites present in biological systems. In this work, this approach has been tested for the detection and identification of the amino acids present in a standard mixture solution and in fish embryo samples. The ROIMCR analysis allowed for the identification of all amino acids present in the analyzed mixtures in both positive and negative modes. The methodology allowed for the direct linking and correspondence between the MS signals in their different acquisition modes. Overall, this approach confirmed the advantages and possibilities of performing the proposed ROIMCR simultaneous analysis of mass spectrometry signals in their differing acquisition modes in untargeted metabolomics studies. Graphical AbstractKeywords
Funding Information
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2020/14688-8)
- Consejo Superior de Investigaciones Científicas (Project CEX2018-000794-S)
- Ministerio de Asuntos Económicos y Transformación Digital, Gobierno de España (PID2019-105732GB-C21)
- Centro de Investigación y desarrollo Pascual Vila
This publication has 40 references indexed in Scilit:
- MCR-ALS GUI 2.0: New features and applicationsChemometrics and Intelligent Laboratory Systems, 2015
- Meat Authentication: A New HPLC–MS/MS Based Method for the Fast and Sensitive Detection of Horse and Pork in Highly Processed FoodJournal of Agricultural and Food Chemistry, 2014
- Multivariate Curve Resolution (MCR). Solving the mixture analysis problemAnalytical Methods, 2014
- Review: ToxicometabolomicsJournal of Applied Toxicology, 2013
- Effect of ionization modifiers on the simultaneous analysis of all classes of phospholipids by nanoflow liquid chromatography/tandem mass spectrometry in negative ion modeJournal of Chromatography A, 2012
- Metabolite identification and quantitation in LC-MS/MS-based metabolomicsTrAC Trends in Analytical Chemistry, 2012
- MassBank: a public repository for sharing mass spectral data for life sciencesJournal of Mass Spectrometry, 2010
- Omics Technology2009
- ESI‐MS/MS analysis of underivatised amino acids: a new tool for the diagnosis of inherited disorders of amino acid metabolism. Fragmentation study of 79 molecules of biological interest in positive and negative ionisation modeRapid Communications in Mass Spectrometry, 2003
- Multivariate curve resolution applied to second order dataChemometrics and Intelligent Laboratory Systems, 1995