Use of magnetic resonance imaging (MRI) in the neonatal intensive care unit has been increasing over the past several years because of improved MRI technology and increased clinical awareness of the prognostic and diagnostic information available. Historically, the use of sedation has been the standard for achieving quality imaging without motion artifact, but it exposed the patient to risks associated with sedation medications. In an effort to obtain MRI studies with elimination of risks associated with sedation, a quality improvement project was initiated. Implementing a standardized approach utilizing a vacuum immobilizer has led to successful neonatal MRI completion without the need for sedation in 94% of study attempts. Acceptable or excellent image quality was achieved in more than 97% of attempts. Time away from the neonatal intensive care unit significantly decreased with this approach, with the mean duration of time away decreasing from 60 to 48 minutes (P < .0001). Obtaining MRI studies without sedation can be successfully implemented in a neonatal intensive care unit, nearly eliminating patient risks associated with sedation while improving utilization of hospital resources and maintaining adequate quality imaging.Keywords
This publication has 18 references indexed in Scilit:
- Anatomic Changes and Imaging in Assessing Brain Injury in the Term InfantClinics in Perinatology, 2008
- Sedation of children under 4 weeks of age for MRI examinationPediatric Anesthesia, 2008
- ACR Guidance Document for Safe MR Practices: 2007American Journal of Roentgenology, 2007
- ENSURING SAFETY FOR INFANTS UNDERGOING MAGNETIC RESONANCE IMAGINGAdvances in Neonatal Care, 2005
- Abnormal Cerebral Structure Is Present at Term in Premature InfantsPediatrics, 2005
- Magnetic resonance imaging under sedation in newborns and infants: a study of 640 cases using sevofluranePediatric Anesthesia, 2005
- Sedation and general anaesthesia in children undergoing MRI and CT: adverse events and outcomesBritish Journal of Anaesthesia, 2000
- Sedation, safety and MRI.British Journal of Radiology, 2000
- Normal brain in human newborns: apparent diffusion coefficient and diffusion anisotropy measured by using diffusion tensor MR imaging.Radiology, 1998
- Safety and efficacy of sedation in children using a structured sedation program.American Journal of Roentgenology, 1997