Abstract
PB samples from 30 healthy volunteers were collected into Vacutainer™ Tubes with clot activator (SST), lithium heparin (LH), dipotassium EDTA (K2E), sodium fluoride/potassium oxalate (NaF/KOx), and buffered/acidic citrate [natrium citrate (9NC), acid-citrate-dextrose (ACD), and citrate-phosphate-dextrose-adenine (CPDA); Becton Dickinson]. After centrifugation at 500g for 15 min at 4 °C, the supernatants and buffy coats were collected and analyzed. Leukocyte subpopulations were obtained after Lympholyte® gradient (5.64% Nycograde™ Polysucrose 400, 9.65% sodium diatrizoate; Cedarlane), and their subset recovery was tested through cytometric analysis (4). Gelatinases from leukocytes and plasma samples were analyzed by gelatin zymography, with 150 μg of total protein loaded on the gel (3). Calibrators were prepared from capillary PB (5). MMP-2 and MMP-9 were measured by ELISA (5). Differences were compared using the Mann–Whitney U-test and the paired t-test; P values <0.05 were statistically significant.

This publication has 7 references indexed in Scilit: