Boron neutron capture therapy of skin melanomas at the RA-6 reactor: A procedural approach to beam set up and performance evaluation for upcoming clinical trials
Authors:
- S. J. GonzálezSGS. J. González
- J. LonghinoJLJ. Longhino
- G. A. Santa CruzGCG. A. Santa Cruz
- O. A. Calzetta LarrieuOLO. A. Calzetta Larrieu
- M. R. BonomiMBM. R. Bonomi
- B. M. C. RothBRB. M. C. Roth
- 15 December 2003
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 31 (1) , 70-80
Abstract
This article reports on the progress of the modeling and experimental characterization of the RA-6 reactor neutron beam, designed for the upcoming BNCT clinical trials of skin melanoma, and presents the first theoretical analysis of such beam performance. The aspects relating to surface source modeling and assessment, beam dosimetry, treatment planning system calibration, and treatment planning optimization are presented herein. Several methods and criteria were established in order to provide guidance for future clinical studies conducted in this facility. Following a realistic model, the theoretical analysis was based on a clinical case of malignant melanoma in extremities. Owing to the complex geometry of the tumor, this particular clinical case represents one of the most difficult lesions to be treated. This article discusses the thorough evaluation stage that has led to the optimization of the treatment planning procedure. Two candidate plans were proposed, and dose-volume distributions in the target volume were evaluated on the basis of the application of a series of criteria that define the critical normal structures which limit the dose delivered. In spite of the complexity of the clinical case under review, results showed that only 4% of the tumor volume is underdosed in cases of mean blood B-10 concentration values, even in the most unfavorable analysis. The overall results suggest that this BNCT facility is prepared to rigorously explore the clinical efficacy of the RA-6 beam and the BNCT treatment modality for peripheral melanomas. (C) 2004 American Association of Physicists in Medicine.Keywords
This publication has 14 references indexed in Scilit:
- Pharamacokinetic modeling for boronophenylalanine-fructose mediated neutron capture therapy:10B concentration predictions and dosimetric consequencesJournal of Neuro-Oncology, 2003
- Reference dosimetry calculations for neutron capture therapy with comparison of analytical and voxel modelsMedical Physics, 2002
- Mass energy‐absorption coefficients and mass collision stopping powers for electrons in tumors of various histologiesMedical Physics, 1999
- The Radiation Biology of Boron Neutron Capture TherapyRadiation Research, 1999
- The elemental composition of tumors: Kerma data for neutronsMedical Physics, 1997
- Mixed field dosimetry of epithermal neutron beams for boron neutron capture therapy at the MITR‐II research reactorMedical Physics, 1994
- The optimal radiation dose per fraction for the treatment of malignant melanomasInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1991
- Determination of boron in biological tissues by inductively coupled plasma atomic emission spectrometryAnalytical Chemistry, 1987
- The role of radiotherapy in recurrent and metastatic malignant melanoma: a clinical radiobiological studyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1986
- The tissue volume factor in radiation oncologyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1982