Abstract
We have developed a method for the non-invasive measurement of urinary bladder pressure, and we apply this method in a longitudinal study of changes in bladder contractility in response to prostatic enlargement. In each volunteer in this study, we measure the bladder pressure twice. In the present study we have used this data to compare the repeatability of the non-invasive method to that of pressure-flow studies in a comparable population of patients. Difference plots were made of non-invasive bladder pressure measurements in 457 volunteers and of pressure-flow studies in a comparable population of 397 male patients. To compare the repeatability of two different methods for clinical measurement, the standard deviation of differences between repeated measurements in one individual needs to be normalised. Often a normalisation by dividing by the mean is done. We show that that normalisation may lead to erroneous results. We have normalised the standard deviations by dividing by the difference between the 97.5th and 2.5th percentile of the mean of the two observations in each subject. Normalised repeatability of the non-invasive method was 0.15, that of the various parameters derived from the pressure-flow studies varied from 0.11 to 0.22. We conclude that the repeatability of the tested non-invasive urodynamic method is comparable to, or slightly better than, that of pressure-flow studies. We further conclude that normalising standard deviations of differences by dividing by the difference between the 97.5th and 2.5th percentile of the mean is a suitable method to compare the repeatability of different methods for clinical measurement.Keywords
This publication has 11 references indexed in Scilit:
- Applicability and reproducibility of condom catheter method for measuring isovolumetric bladder pressureUrology, 2004
- A flow rate cut-off value as a criterion for the accurate non-invasive measurement of bladder pressure using a condom-type catheterUrological Research, 2003
- Development of a non‐invasive strategy to classify bladder outlet obstruction in male patients with LUTSNeurourology and Urodynamics, 2002
- THE VARIABLE OUTFLOW RESISTANCE CATHETER:: A NEW METHOD TO MEASURE BLADDER PRESSURE NONINVASIVELYJournal of Urology, 2001
- Variability of pressure-flow studies in men with lower urinary tract symptomsNeurourology and Urodynamics, 2000
- Non-invasive measurement of bladder pressure using an external catheterNeurourology and Urodynamics, 1999
- REPEAT NONINVASIVE BLADDER PRESSURE MEASUREMENTS WITH AN EXTERNAL CATHETERJournal of Urology, 1999
- Bladder outlet obstruction index, bladder contractility index and bladder voiding efficiency: three simple indices to define bladder voiding functionBJU International, 1999
- Quantification of urethral resistance and bladder function during voiding, with special reference to the effects of prostate size reduction on urethral obstruction due to benign prostatic hyperplasiaNeurourology and Urodynamics, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986