Abstract
The objective is to evaluate the parameters significantly related to calculating the power of the implanted lens and to determine the importance of different biometric, retina, and corneal aberrations variables. A retrospective cross-sectional observational study used a database of 422 patients who underwent cataract surgery at the Oftalvist Center in Almeria between January 2021 and December 2022. A random forest based on machine learning techniques was proposed to classify the importance of preoperative variables for calculating IOL power. Correlations were explored between implanted IOL power and the most important variables in random forests. The importance of each variable was analyzed using the random forest technique, which established a ranking of feature selections based on different criteria. A positive correlation was found with the random forest variables. Selection: axial length (AL), keratometry preoperative, anterior chamber depth (ACD), measured from corneal epithelium to lens, corneal diameter, lens constant, and astigmatism aberration. The variables coma aberration (p-value = 0,12) and macular thickness (p-value = 0,10) were almost slightly significant. In cataract surgery, the implanted IOL power is mainly correlated with axial length, anterior chamber depth, corneal diameter, lens constant, and preoperative keratometry. New variables such as astigmatism and anterior coma aberration and retina variables such as the preoperative central macular thickness could be included in the new generation of biometric formulas based on artificial intelligence techniques.Keywords
This publication has 16 references indexed in Scilit:
- Accuracy of Intraocular Lens Calculation FormulasOphthalmology, 2018
- C constant: New concept for ray tracing–assisted intraocular lens power calculationJournal of Cataract & Refractive Surgery, 2014
- Comparison of Hoffer Q and Haigis Formulae for Intraocular Lens Power Calculation According to the Anterior Chamber Depth in Short EyesAmerican Journal of Ophthalmology, 2014
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisGraefe's Archive for Clinical and Experimental Ophthalmology, 2000
- Refractive and visual outcome of hyperopic cataract cases operated on before and after implementation of the Holladay II formulaOphthalmology, 1998
- An improved universal theoretical formula for intraocular lens power predictionJournal of Cataract & Refractive Surgery, 1993
- The Hoffer Q formula: A comparison of theoretic and regression formulasJournal of Cataract & Refractive Surgery, 1993
- Development of the SRK/T intraocular lens implant power calculation formulaJournal of Cataract & Refractive Surgery, 1990
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988
- Anterior zonular shifts with ageExperimental Eye Research, 1979