Validation of an HR-pQCT-based homogenized finite element approach using mechanical testing of ultra-distal radius sections
- 5 August 2010
- journal article
- research article
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 10 (4) , 431-444
Abstract
Osteoporotic (Colles’ type) fractures of the distal radius occur relatively early in lifetime and could estimate risk of fracture of other, more endangered anatomical sites. High-resolution peripheral quantitative computed tomography (HR-pQCT) based micro finite element (μFE) analysis was shown to better predict fracture load of the distal radius than densitometry or histomorphometric measures. As an alternative to μFE, homogenization-based FE (hFE) approach may provide at least equivalent predictive power with reduced computational needs. The aim of this study was to validate the hFE approach with compression tests of 25 distal radius sections extracted at the location which is relevant in Colles’ fractures. HR-pQCT-based input parameters of the hFE models were calibrated with respect to μCT. HR-pQCT-based hFE models were then built and their ability to predict experimental stiffness and ultimate load was compared to those of the density-based parameters, histomorphometric indices and μFE models assessed from the same input images. Bone mineral content was the best non-FE-based predictor (R 2 = 0.86) of ultimate force. Both FE methods were not only the strongest predictors, but provided quantitatively correct fracture loads. The calibrated hFE approach provided closely as strong prediction (R 2 = 0.94) as μFE (R 2 = 0.95), but the former was computationally cheaper. The results of this validation study suggest that FE simulation could be used as an efficient and precise tool to predict Colles’ fracture load.Keywords
This publication has 40 references indexed in Scilit:
- A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitroJournal of Biomechanics, 2010
- Automated simulation of areal bone mineral density assessment in the distal radius from high-resolution peripheral quantitative computed tomographyOsteoporosis International, 2009
- A patient-specific finite element methodology to predict damage accumulation in vertebral bodies under axial compression, sagittal flexion and combined loadsComputer Methods in Biomechanics and Biomedical Engineering, 2008
- Finite Element Analysis Based on In Vivo HR-pQCT Images of the Distal Radius Is Associated With Wrist Fracture in Postmenopausal WomenJournal of Bone and Mineral Research, 2008
- Automatic segmentation of cortical and trabecular compartments based on a dual threshold technique for in vivo micro-CT bone analysisBone, 2007
- A scalable multi‐level preconditioner for matrix‐free µ‐finite element analysis of human bone structuresInternational Journal for Numerical Methods in Engineering, 2007
- Strength Prediction of the Distal Radius by Bone Densitometry—Evaluation Using Biomechanical TestsAnnals of Biomedical Engineering, 2004
- Osteoporosis Intervention Following Distal Forearm FracturesArchives of internal medicine (1960), 2002
- Lumbar vertebral body compressive strength evaluated by dual-energy X-ray absorptiometry, quantitative computed tomography, and ashingBone, 1999
- Unequal decrease in bone density of lumbar spine and ultradistal radius in Colles' and vertebral fracture syndromes.Journal of Clinical Investigation, 1989