Leadless atrial versus transvenous pacing for sinus node dysfunction: 1-year outcomes from the leadless ARRIVE real-world study
Authors:
- Kent R NilssonKNKent R Nilsson
- Shmaila Saleem-TalibSSShmaila Saleem-Talib
- Deepti BettampadiDBDeepti Bettampadi
- Jorge O DiazJDJorge O Diaz
- James K GabrielsJGJames K Gabriels
- Robert D SchallerRSRobert D Schaller
- Himanshu H ShuklaHSHimanshu H Shukla
- Michael KühneMKMichael Kühne
- Mauro BiffiMauro Biffi
- Daniel HoferDHDaniel Hofer
Open Access
- 30 March 2026
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (4)
Abstract
Background and Aims: Leadless pacing was developed to avoid complications inherent to transvenous (TV) pacemakers. Among patients with sinus node dysfunction (SND) without atrioventricular block (AVB), TV systems remain standard therapy. Real-world data have shown favourable safety profiles for leadless vs. TV pacemakers. This study aimed to compare 30-day complications and 1-year outcomes—including complications, device-reinterventions, and all-cause mortality—between AVEIR AR leadless pacemakers (LP) and dual-chamber (DCTV) or right-atrial (RATV) TV pacemakers. Methods: Medicare fee-for-service claims were analysed to identify patients undergoing de novo AVEIR AR LP or TV pacemaker implantation from January 2024 to March 2025, with ≥1 year of prior and ≥30 days of post-implant continuous enrolment. The DCTV cohort included patients with SND without permanent atrial fibrillation or AVB; the RATV and LP cohorts included all respective recipients. Outcomes included 30-day and 1-year complications, device-reinterventions, and mortality. Comparisons were adjusted using propensity score derived overlap weights. Results: A total of 428 AVEIR AR, 39 881 DCTV, and 389 RATV patients were included. Thirty-day complications were lower with AVEIR AR compared with DCTV (adjusted 6.7% vs. 9.4%; OR = 0.7) and similar to RATV (6.9% vs. 6.7%). At 1 year, overall complications remained lower in AVEIR AR than DCTV (3.6% vs. 8.5%; HR = 0.4) and RATV (3.3% vs. 7.5%; HR = 0.4) cohorts. Device-related complications were reduced vs. DCTV, and reinterventions were reduced vs. both DCTV and RATV. Mortality was comparable across all groups. Conclusion: AVEIR AR was associated with fewer long-term complications and reinterventions compared with DCTV and RATV, while 1-year mortality remained similar.Keywords
Funding Information
- Abbott Laboratories
This publication has 24 references indexed in Scilit:
- 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm SocietyCirculation, 2019
- Complications and Health Care Costs Associated With Transvenous Cardiac Pacemakers in a Nationwide AssessmentJACC: Clinical Electrophysiology, 2017
- Progression of paroxysmal to persistent atrial fibrillation: 10-year follow-up in the Canadian Registry of Atrial FibrillationHeart Rhythm, 2017
- Permanent Leadless Cardiac Pacemaker TherapyCirculation, 2017
- Sinus Node and Atrial ArrhythmiasCirculation, 2016
- Percutaneous Implantation of an Entirely Intracardiac Leadless PacemakerThe New England journal of medicine, 2015
- Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in DenmarkEuropean Heart Journal, 2013
- 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapyEuropean Heart Journal, 2013
- Incidence and predictors of short- and long-term complications in pacemaker therapy: The FOLLOWPACE studyHeart Rhythm, 2012
- Linking inpatient clinical registry data to Medicare claims data using indirect identifiersAmerican Heart Journal, 2009