Computer-Assisted Audiometry Versus Manual Audiometry
Authors:
- Allan Thiam Poh HoAHAllan Thiam Poh Ho
- Anthony J. HildrethAHAnthony J. Hildreth
- Leon LindseyLLLeon Lindsey
- 1 October 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 30 (7) , 876-883
Abstract
The Otogram is an automated computer-assisted audiometer that allows patients to self-administer audiometry for their pure-tone audiogram. There has been no research published in a peer-reviewed journal, validating its use in an otology outpatient clinic. We therefore proposed to investigate and compare the inter-rater and intrarater accuracy and reliability of audiologists and of the Otogram in an English-speaking British population. Prospective nonrandomized validation study. Secondary otolaryngology center and otology outpatient clinic. Forty-eight NHS patients referred to an otology outpatient clinic. Each patient had 2 pure-tone audiograms. Hearing thresholds in decibels hearing level were ascertained by fully trained British audiologists and by the Otogram. Using the weighted kappa statistic, the level of agreement in air-conduction (kappa = 0.965) and bone-conduction (kappa = 0.927) thresholds between the audiologist and the Otogram on the same patient was equivalent to the inter-rater level of agreement between pairs of audiologists. Approximately 94% of air-conduction thresholds and 91% of bone-conduction thresholds measured by the Otogram fell within 10 dB of thresholds measured by an audiologist. Intrarater comparisons between audiologists were very good for air-conduction (kappa = 0.978) and bone-conduction (kappa = 0.964). The intrarater level of agreement between repeated Otogram thresholds was just as good for air-conduction (kappa = 0.974) and bone-conduction (kappa = 0.945) thresholds. The Otogram is just as reliable as audiologists at determining hearing thresholds. We recommend that the Otogram can be safely used in a controlled clinical setting supervised by audiologists.Keywords
This publication has 11 references indexed in Scilit:
- Manual Audiometry vs Self‐Automated Otogram: A Comparison of Testing OutcomesOtolaryngology–Head and Neck Surgery, 2004
- Computer-Assisted Audiometry and Technicians in a High-Volume PracticeAmerican Journal of Audiology, 1993
- Recommended procedure for pure-tone bone-conduction audiometry without masking using a manually operated instrumentBritish Journal of Audiology, 1985
- BAOL/BSA Method for Assessment of Hearing DisabilityBritish Journal of Audiology, 1983
- Recommended Procedures for Pure-tone Audiometry Using a Manually Operated InstrumentBritish Journal of Audiology, 1981
- Modification and Application of the Computerized Automatic AudiometerScandinavian Audiology, 1978
- Computer AudiometryJournal of Speech and Hearing Research, 1974
- Computerized Pure-Tone Audiometric ProceduresJournal of Speech and Hearing Research, 1973
- An Automatic Audiometer for Air Force Classification CentersNoise Control, 1956
- An Automatic Audiometer for Industrial MedicineNoise Control, 1956