The Design and Construction of the MICE Spectrometer Solenoids
Authors:
- Michael S. ZismanMZMichael S. Zisman
- Steve P. VirostekSVSteve P. Virostek
- Michael A. GreenMGMichael A. Green
- 23 June 2009
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 1348-1351
Abstract
The purpose of the MICE spectrometer solenoid is to provide a uniform field for a scintillating fiber tracker. The uniform field is produced by a long center coil and two short end coils. Together, they produce 4T field with a uniformity of better than 1% over a detector region of 1000 mm long and 300 mm in diameter. Throughout most of the detector region, the field uniformity is better than 0.3%. In addition to the uniform field coils, we have two match coils. These two coils can be independently adjusted to match uniform field region to the focusing coil field. The coil package length is 2544 mm. We present the spectrometer solenoid cold mass design, the powering and quench protection circuits, and the cryogenic cooling system based on using three cryocoolers with re-condensers.Keywords
This publication has 6 references indexed in Scilit:
- Quench Protection for the MICE Cooling Channel Coupling MagnetIEEE Transactions on Applied Superconductivity, 2009
- The Engineering Design of the 1.5 m Diameter Solenoid for the MICE RFCC ModulesIEEE Transactions on Applied Superconductivity, 2008
- The Design Parameters for the MICE Tracker SolenoidIEEE Transactions on Applied Superconductivity, 2007
- The Mechanical and Thermal Design for the MICE Focusing Solenoid Magnet SystemIEEE Transactions on Applied Superconductivity, 2005
- The Mechanical and Thermal Design for the MICE Detector Solenoid Magnet SystemIEEE Transactions on Applied Superconductivity, 2005
- Muon collidersAIP Conference Proceedings, 1996