Analysis of bone demineralization due to the use of exoprosthesis by comparing Young’s Modulus of the femur in unilateral transfemoral amputees
Open Access
- 1 December 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 35 (4) , 459-466
Abstract
Background: There is a relation between Hounsfield units obtained from computed tomography (CT) scans and bone density. The density of the bones can be used to establish its mechanical properties and therefore to assess the bone mechanical condition using CT images. Objectives: To identify the effect of the transfemoral amputation and the use of external lower limb prosthesis in the bone properties, by comparing Young’s modulus. Study Design: Young’s modulus comparison. Methods: Comparison of bone density between the healthy femur and the amputated bone of 20 unilateral transfemoral amputees was done by generating three histograms of the Hounsfield units at different parts of the femur. The histograms were created based on images obtained by CT and the Hounsfield units were translated to Young’s modulus to establish the comparison. Results: The results show a significant difference (p-value Conclusions: There is clearly a direct association between the use of external prosthesis and the bone demineralization due the stress shielding phenomenon. The Young’s modulus comparison using information from CT images can be a suitable tool to analyze the bone demineralization due to the use of exoprosthesis.Keywords
This publication has 38 references indexed in Scilit:
- Validation of subject-specific automated p-FE analysis of the proximal femurJournal of Biomechanics, 2009
- Prediction of mechanical properties of cortical bone by quantitative computed tomographyMedical Engineering & Physics, 2007
- Real-Time Patient-Specific Finite Element Analysis of Internal Stresses in the Soft Tissues of a Residual Limb: A New Tool for Prosthetic FittingAnnals of Biomedical Engineering, 2006
- Load transfer mechanics between trans-tibial prosthetic socket and residual limb—dynamic effectsJournal of Biomechanics, 2004
- Mechanical properties, density and quantitative CT scan data of trabecular bone with and without metastasesJournal of Biomechanics, 2004
- Simulation of Trabecular Surface Remodeling based on Local Stress Nonuniformity.JSME International Journal Series C, 1997
- Development of a non-linear finite element modelling of the below-knee prosthetic socket interfaceMedical Engineering & Physics, 1995
- Predicting the compressive mechanical behavior of boneJournal of Biomechanics, 1994
- Automated three-dimensional finite element modelling of bone: a new methodJournal of Biomedical Engineering, 1990