Abstract
Charge-state-resolved ion energy distribution functions were measured for pulsed cathodic arcs taking the sheath into account that formed between the plasma and the entrance of a combined energy and mass spectrometer. An electron emitting probe was employed to independently determine the plasma potential. All results were obtained by averaging over several individual measurements because the instantaneous energy distributions and the plasma potential show large amplitude fluctuations due to the explosive nature of the arc plasma generation. It was found that the ion energy distribution functions in the plasma were independent of the ion charge state. This is in contrast to findings with continuously operating, direct-current arcs that employ a magnetic field at the cathode to steer the cathode spot motion. The different findings indicate the important role of the magnetic steering field for the plasma properties of direct-current arcs. The results are further supported by experiments with “biased plasmas” obtained by shifting the potential of the anode. Finally, it was shown that the ion energy distributions were broader and shifted to higher energy at the beginning of each arc pulse. The characteristic time for relaxation to steady state distributions is about 100μs .

This publication has 26 references indexed in Scilit: