Regional variations of T2* in healthy and pathologic achilles tendon in vivo at 7 Tesla: Preliminary results
Open Access
- 3 January 2012
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 68 (5) , 1607-1613
Abstract
The aim of this study was to investigate T in the Achilles tendon (AT), in vivo, using a three‐dimensional ultrashort time echo (3D‐UTE) sequence, to compare field strength differences (3 and 7 T) and to evaluate a regional variation of T in healthy and pathologic tendon. Ten volunteers with no history of pain in the AT and five patients with chronic Achilles tendinopathy were recruited. 3D‐UTE images were measured with the following echo times, at echo time = [0.07, 0.2, 0.33, 0.46, 0.59, 0.74, 1.0, 1.5, 2.0, 4.0, 6.0, and 9.0 ms]. T values in the AT were calculated by fitting the signal decay to biexponential function. Comparing volunteers between 3 and 7 T, short component T was 0.71 ± 0.17 ms and 0.34 ± 0.09 ms (P < 0.05); bulk long component T was 12.85 ± 1.87 ms and 10.28 ± 2.28 ms (P < 0.05). In patients at 7 T, bulk T was 0.53 ± 0.17 ms (P = 0.045, compared to volunteers), T was 11.49 ± 4.28 ms (P = 0.99, compared to volunteers). The results of this study suggest that the regional variability of AT can be quantified by T in in vivo conditions. Advanced quantitative imaging of the human AT using a 3D‐UTE sequence may provide additional information to standard clinical imaging. Finally, as the preliminary patient data suggest, T may be a promising marker for the diagnosis of pathological changes in the AT. Magn Reson Med, 2012.Keywords
Funding Information
- Vienna Spots of Excellence des Wiener Wissenschafts-und Technologie-Fonds (WWTF) and Vienna Advanced Imaging Center
- VIACLIC and the Slovak Scientific Grant Agency VEGA (2/0090/11)
This publication has 21 references indexed in Scilit:
- In vitro evaluation of a manganese chloride phantom-based MRI technique for quantitative determination of lumbar intervertebral disc composition and conditionEuropean Spine Journal, 2010
- Assessing degeneration of human articular cartilage with ultra-short echo time (UTE) T2* mappingOsteoarthritis and Cartilage, 2010
- 10.1007/978-1-84628-629-2_22010
- High resolution imaging of the knee on 3‐Tesla MRI: A pictorial reviewClinical Anatomy, 2008
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Selective 3D ultrashort TE imaging: comparison of “dual-echo” acquisition and magnetization preparation for improving short-T 2 contrastMagnetic Resonance Materials in Physics, Biology and Medicine, 2007
- 3D radial projection technique with ultrashort echo times for sodium MRI: Clinical applications in human brain and skeletal muscleMagnetic Resonance in Medicine, 2006
- Mechanobiology of tendonJournal of Biomechanics, 2006
- Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequencesClinical Radiology, 2004
- "Magic-angle" phenomenon: a cause of increased signal in the normal lateral meniscus on short-TE MR images of the knee.American Journal of Roentgenology, 1994