When Nothing Goes Right: Risk Factors and Biomarkers of Right Heart Failure after Left Ventricular Assist Device Implantation
Authors:
- Thomas SchlöglhoferThomas Schlöglhofer
- Franziska WittmannFWFranziska Wittmann
- Robert PausRPRobert Paus
- Julia RiebandtJRJulia Riebandt
- Anne-Kristin SchaeferASAnne-Kristin Schaefer
- Philipp AngleitnerPAPhilipp Angleitner
- Marcus GraneggerMarcus Granegger
- Philipp AignerPAPhilipp Aigner
- Dominik WiedemannDominik Wiedemann
- Günther LauferGLGünther Laufer
- Heinrich SchimaHSHeinrich Schima
- Daniel ZimpferDaniel Zimpfer
Open Access
Abstract
Right heart failure (RHF) is a severe complication after left ventricular assist device (LVAD) implantation. The aim of this study was to analyze the incidence, risk factors, and biomarkers for late RHF including the possible superiority of the device and implantation method. This retrospective, single-center study included patients who underwent LVAD implantation between 2014 and 2018. Primary outcome was freedom from RHF over one-year after LVAD implantation; secondary outcomes included pre- and postoperative risk factors and biomarkers for RHF. Of the 145 consecutive patients (HeartMate 3/HVAD: n = 70/75; female: 13.8%), thirty-one patients (21.4%) suffered RHF after a mean LVAD support of median (IQR) 105 (118) days. LVAD implantation method (less invasive: 46.7% vs. 35.1%, p = 0.29) did not differ significantly in patients with or without RHF, whereas the incidence of RHF was lower in HeartMate 3 vs. HVAD patients (12.9% vs. 29.3%, p = 0.016). Multivariate Cox proportional hazard analysis identified HVAD (HR 4.61, 95% CI 1.12–18.98; p = 0.03), early post-op heart rate (HR 0.96, 95% CI 0.93–0.99; p = 0.02), and central venous pressure (CVP) (HR 1.21, 95% CI 1.05–1.39; p = 0.01) as independent risk factors for RHF, but no association of RHF with increased all-cause mortality (HR 1.00, 95% CI 0.99–1.01; p = 0.50) was found. To conclude, HVAD use, lower heart rate, and higher CVP early post-op were independent risk factors for RHF following LVAD implantation.Keywords
This publication has 28 references indexed in Scilit:
- Left ventricular vs. biventricular mechanical support: Decision making and strategies for avoidance of right heart failure after left ventricular assist device implantationInternational Journal of Cardiology, 2015
- Right ventricular failure after left ventricular assist devicesThe Journal of Heart and Lung Transplantation, 2015
- Ventricular assist devices: The future is nowTrends in Cardiovascular Medicine, 2015
- Outcomes and Predictors of Early Mortality After Continuous-Flow Left Ventricular Assist Device Implantation as a Bridge to TransplantationASAIO Journal, 2014
- Load Dependency of Right Ventricular Performance Is a Major Factor to be Considered in Decision Making Before Ventricular Assist Device ImplantationCirculation, 2013
- Predicting Right Ventricular Failure in the Modern, Continuous Flow Left Ventricular Assist Device EraThe Annals of Thoracic Surgery, 2013
- Implantation of a centrifugal pump as a left ventricular assist device through a novel, minimized approach: Upper hemisternotomy combined with anterolateral thoracotomyThe Journal of Thoracic and Cardiovascular Surgery, 2012
- Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomesThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Risk Factors Predictive of Right Ventricular Failure After Left Ventricular Assist Device ImplantationThe American Journal of Cardiology, 2010
- Deleterious Effects of β-Blockers on Exercise Capacity and Hemodynamics in Patients With Portopulmonary HypertensionGastroenterology, 2006