NUMERICAL SIMULATIONS OF STEEL FLOOR STRUCTURES CONSIDERING LARGE DEFORMATIONS UNDER ELEVATED TEMPERATURES IN FIRES
Authors:
- 1 January 2020
- journal article
- research article
- Published by Architectural Institute of Japan in Journal of Structural and Construction Engineering (Transactions of AIJ)
- Vol. 85 (768) , 287-297
Abstract
In this research, the behavior of steel floor structures, which are composed of steel beams, concrete slabs and bolted connections, under elevated temperatures in fires are numerically simulated using detailed FEM models. The simulations account for the inelastic temperature-dependent material properties and thermal elongations, considering the large deformation. The findings are as follows: 1) The simulation models of the components of the floor structures, such as beams, slabs and bolted connections were independently validated by comparing with existing experimental data at elevated temperatures. Deflections of composite beams agreed between the results of the experiments and simulations, where beams and slabs are modeled with shell elements. 2) The created FEM models of reinforced concrete slabs simulate the experiments well. The deflections at the elevated temperatures agreed, taking into account the thermal distribution in the sections. The simulated stress of the reinforcement significantly increased in the center and corners of the slab, where the slab cracked and ruptured in the experiment. 3) Shear failure of high-strength bolts is a major failure mode of simple bolted connections in fires. The inelastic shear force displacement relationships at elevated temperatures are defined by reviewing the existing experimental data and are applied for the springs of bolts. The principle direction of the shear forces of bolts in beam ends may change with respect to beam sagging and consequently generate tensile axial forces of the beams at elevated temperatures. The created bolt springs return the reactions in the changing principle shear directions. The behavior and shear failure of simple bolted connections at elevated temperatures in the existing experiment are reasonably simulated using the models. 4) FEM models of a one-bay floor structure composed of primary and secondary beams and concrete slabs are modeled with shell elements. Insulated primary beams located on the perimeter of the rectangular bay are rigidly supported at the ends, and two uninsulated secondary beams are supported by the primary beams. Shear springs for the bolts are used for the simple bolted connections at the secondary beam ends. In the case that the bay is internally located in the plan of a building and the slab edges are rigidly supported at the perimeter, shear failure of the bolted connections of the secondary beams may occur due to thermal expansion under elevated temperatures. Sagging increases, and the slab cracks at the center and corner of the bay. However, catenary effect can maintain the vertical load carrying capacity associated with yielding of the reinforcement, given that the reinforcement is perfectly bonded to the slabs. 5) The simulations of the one-bay floor structure are conducted under various conditions. It is found that the uninsulated secondary beams may reduce the deflection at the beam temperatures of 600℃ or lower, and the catenary effect of slabs play an important role in carrying the vertical load at higher temperatures. The quantity of slab reinforcement influences the deflection in the catenary effect.Keywords
This publication has 12 references indexed in Scilit:
- CRITICAL TEMPERATURE OF STEEL BEAMS ON THE BASIS OF A LOAD-BEARING FIRE TEST OF 2-STOREY RIGID STEEL FRAMEJournal of Structural and Construction Engineering (Transactions of AIJ), 2014
- Predicting the Standard Fire Behavior of Composite Steel Beams2011
- Tying capacity of web cleat connections in fire, Part 2: Development of component-based modelEngineering Structures, 2009
- Experimental investigation of the behaviour of fin plate connections in fireJournal of Constructional Steel Research, 2009
- Numerical simulation of bolted steel connections in fire using explicit dynamic analysisJournal of Constructional Steel Research, 2008
- EXPERIMENTAL STUDY ON ULTIMATE FLEXURAL STRENGTH OF COMPOSITE BEAM IN FIREJournal of Structural and Construction Engineering (Transactions of AIJ), 2008
- Behaviour of concrete floor slabs at ambient and elevated temperaturesFire Safety Journal, 2007
- EXPERIMENTAL STUDY ON SHEAR DEFORMATION BEHAVIOR OF HIGH STRENGTH BOLTS AT ELEVATED TEMPERATUREJournal of Structural and Construction Engineering (Transactions of AIJ), 2007
- THREE DIMENSIONAL ANALYSIS OF DEFLECTION BEHAVIOUR ABOUT STEEL FRAMES EXPOSED TO FIREJournal of Structural and Construction Engineering (Transactions of AIJ), 2005
- Behavior and Modeling of a Bolt Bearing on a Single PlateJournal of Structural Engineering, 2003