Improving dynamic susceptibility contrast MRI measurement of quantitative cerebral blood flow using corrections for partial volume and nonlinear contrast relaxivity: A xenon computed tomographic comparative study
Open Access
- 28 September 2009
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 30 (4) , 743-752
Abstract
Purpose: To test whether dynamic susceptibility contrast MRI‐based CBF measurements are improved with arterial input function (AIF) partial volume (PV) and nonlinear contrast relaxivity correction, using a gold‐standard CBF method, xenon computed tomography (xeCT).Materials and Methods: Eighteen patients with cerebrovascular disease underwent xeCT and MRI within 36 h. PV was measured as the ratio of the area under the AIF and the venous output function (VOF) concentration curves. A correction was applied to account for the nonlinear relaxivity of bulk blood (BB). Mean CBF was measured with both techniques and regression analyses both within and between patients were performed.Results: Mean xeCT CBF was 43.3 ± 13.7 mL/100g/min (mean ± SD). BB correction decreased CBF by a factor of 4.7 ± 0.4, but did not affect precision. The least‐biased CBF measurement was with BB but without PV correction (45.8 ± 17.2 mL/100 g/min, coefficient of variation [COV] = 32%). Precision improved with PV correction, although absolute CBF was mildly underestimated (34.3 ± 10.8 mL/100 g/min, COV = 27%). Between patients correlation was moderate even with both corrections (R = 0.53).Conclusion: Corrections for AIF PV and nonlinear BB relaxivity improve bolus MRI‐based CBF maps. However, there remain challenges given the moderate between‐patient correlation, which limit diagnostic confidence of such measurements in individual patients. J. Magn. Reson. Imaging 2009;30:743–752.Keywords
This publication has 35 references indexed in Scilit:
- Comparative Overview of Brain Perfusion Imaging TechniquesStroke, 2005
- Absolute CBF and CBV measurements by MRI bolus tracking before and after acetazolamide challenge: Repeatabilily and comparison with PET in humansNeuroImage, 2005
- Automated Method for Generating the Arterial Input Function on Perfusion-Weighted MR Imaging: Validation in Patients with Stroke2005
- Measurement of cerebral perfusion with dual‐echo multi‐slice quantitative dynamic susceptibility contrast MRIJournal of Magnetic Resonance Imaging, 1999
- Correlation of Regional Cerebral Blood Flow Measured by Stable Xenon CT and Perfusion MRIJournal of Computer Assisted Tomography, 1999
- Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking: Comparison with [15O]H2O Positron Emission Tomography in HumansJournal of Cerebral Blood Flow & Metabolism, 1998
- Qualitative Versus Quantitative Assessment of Cerebrovascular ReservesNeurosurgery, 1998
- Absolute Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking: Comparison with Positron Emission Tomography ValuesJournal of Cerebral Blood Flow & Metabolism, 1998
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging.Radiology, 1994